In buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, the maximum allowable area of unprotected openings in occupancies other than Groups...
Search Results "Sprinkler System"
Commonly Searched Documents
-
704.8.1 Automatic sprinkler system
-
[F] SECTION 903
AUTOMATIC SPRINKLER SYSTEMS
[F] SECTION 903 AUTOMATIC SPRINKLER SYSTEMS...
-
903.3.1 Standards
Sprinkler systems shall be designed and installed in accordance with Sections 903.3.1.1, 903.3.1.2 or 903.3.1.3....
-
903.3.1.1.1 Exempt locations
Automatic sprinklers shall not be required in the following rooms or areas where such rooms or areas are protected with an approved automatic fire detection system in accordance with Section...
-
1009.2.1 Elevators required
Exceptions: In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1 or 903.3.1.2, the elevator shall not be required on floors...
-
704.9 Vertical separation of openings
This section shall not apply to buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. Open parking garages....
-
903.3.1.1 NFPA 13 sprinkler systems
Where the provisions of this code require that a building or portion thereof be equipped throughout with an automatic sprinkler system, sprinklers shall be installed throughout in accordance...
-
903.3.1.2 NFPA 13R sprinkler systems
Where allowed in buildings of Group R, up to and including four stories in height, automatic sprinkler systems shall be installed throughout in accordance with NFPA 13R....
-
1009.7.4 Stairways
Exception: The minimum clear width of 48 inches (1220 mm) between handrails is not required at stairways serving buildings equipped throughout with an automatic sprinkler system installed...
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
907.2.1 Group A
A manual fire alarm system shall be installed in accordance with NFPA 72 in Group A occupancies having an occupant load of 300 or more....
-
1009.2.1 Elevators required
In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with...
-
1009.2.1 Elevators required
Exceptions: In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1 or 903.3.1.2, the elevator shall not be required on floors...
-
1007.2.1 Elevators required
In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with...
-
907.2.4 Group F
A manual fire alarm system shall be installed in Group F occupancies that are two or more stories in height and have an occupant load of 500 or more above or below the lowest level of exit...
-
907.2.2 Group B
A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
1007.2.1 Buildings with four or more stories
Exceptions: In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on...
-
1003.2.13.1.1 Buildings with four or more stories
In buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with...
-
907.2.3 Group E
A manual fire alarm system shall be installed in Group E occupancies....
-
1007.6.2 Separation
Areas of refuge where the area of refuge and areas served by the area of refuge are equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1...
-
1003.2.13.5.2 Separation
Areas of refuge where the area of refuge and areas served by the area of refuge are equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1...
-
A4.1.3(9)
A4.1.3(9) Supervised automatic sprinkler systems have built in signals for monitoring features of the system such as the opening and closing of water control valves, the power supplies for...
-
1009.3 Stairways
In order to be considered part of an accessible means of egress, a stairway between stories shall comply with Sections 1009.3.1 through 1009.3.3. [DSA·AC & HCD 1-AC] In addition,...
-
Area of Refuge Identification [IBC §1007.6.5 (2003), §1003.2.13.5.5 (2000)]
Sample Area of Refuge and Exit Sign Areas of refuge are not required in facilities that are equipped throughout with an automated sprinkler systems in compliance with the IBC...