E. Hallways and Corridors
-
E. Hallways and Corridors
Hallways and Corridors...
-
Are requirements for protruding objects limited to hallways and corridors?
No, requirements for protruding objects apply to all circulation paths, including those in rooms and spaces off corridors. They apply to both interior and exterior circulation paths....
-
Minimum Clear Corridor Width
A few commenters from the disability community advocated a minimum clear corridor width of 48 inches....
-
1. Typical Issues for Individuals Who Use Wheelchairs, Scooters, or Other Mobility Devices
Typically made up of hallways, corridors, and interior rooms and spaces, the accessible route is essential for people who have difficulty walking or who use wheelchairs or other mobility...
-
Part 1. Typical Issues for Voters Who Use Wheelchairs, Scooters, or Other Mobility Devices
Typically made up of hallways, corridors, and interior rooms and spaces, the accessible route is essential for people who have difficulty walking or who use wheelchairs or other mobility...
-
4.3.11.1(3)
(3) A portion of a one-hour fire-resistive corridor (complying with local requirements for fire-resistive construction and for openings) located immediately adjacent to an exit enclosure...
-
11B-403.5.1 Clear width
The clear width for walking surfaces in corridors serving an occupant load of 10 or more shall be 44 inches (1118 mm) minimum....
-
General: ADA Standard Section 401
Section 401 of the ADA Standards covers information in the current ADA Standards for accessible routes.
-
11B-401 General
[See subsections ...]
-
E2-b
E2-b. Are pedestrian routes leading to or serving each of the service or activity areas free of overhead objects with the bottom edge lower than 80 inches above the floor? [ADA...
-
E1-a
E1-a. Is there an accessible route, at least 36 inches wide, that connects the accessible entrance to all shelter areas (it may narrow to 32 inches wide for up to 2 feet in length)?...
-
E2-a
E2-a. Are pedestrian routes leading to or serving each service or activity area of the shelter free of objects that protrude from the side more than 4 inches into the route with the...
-
E2-2. Overhead Objects
E2-2. Are pedestrian routes leading to or serving the voting area free of overhead objects with the bottom edge lower than 80 inches above the floor? Yes _____ No _____ If No,...
-
E1-1. Accessible Route
E1-1. Is there an accessible route, at least 36 inches wide that connects the accessible entrance to the voting area (the accessible route may narrow to 32 inches wide for up to 2...
-
4.3.1* GENERAL
All walks, halls, corridors, aisles, and other spaces that are part of an accessible route shall comply with 4.3....
-
4.3.1* General
All walks, halls, corridors, aisles, skywalks, tunnels, and other spaces that are part of an accessible route shall comply with 4.3....
-
2. Typical Issues for People Who are Blind or Have Low Vision
That means any area where people using the shelter can walk, including hallways, corridors, eating areas, and sleeping areas, must be free of objects that cannot be detected by a person...
-
Part 2. Typical Issues for Voters Who are Blind or Who Have Low Vision
That means pedestrian routes open to voters serving or leading to the voting area, such as hallways, corridors and the voting space, must be free of objects that cannot be detected by a...
-
E1-b
E1-b. Is the accessible route free of steps and abrupt level changes over 1/2 inch? Yes No Note: level changes between 1/4 inch and 1/2 inch should be beveled). [ADA...
-
E1-2. Accessible Route
E1-2. Is the accessible route free of steps and abrupt level changes over 1/2 inch (level changes between 1/4 inch and 1/2 inch should be beveled)? [ADA Stds 4.1.3(1), 4.3.8] Yes...
-
E2-3. Interior Stairs
E2-3. If provided, are the interior stairs along these routes built so that people who are blind or visually impaired cannot hit their heads on the underside (i.e., protected with a...
-
11B-403.5.1 Clear width
The clear width for walking surfaces in corridors serving an occupant load of 10 or more shall be 44 inches (1118 mm) minimum. 3....
-
11B-403.5.1 Clear width
The clear width for walking surfaces in corridors serving an occupant load of 10 or more shall be 44 inches (1118 mm) minimum....