[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
Search Results "Ramp Slope"
-
11B-404.2.5 Thresholds
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-206.2.3.2 Distance to Elevators
new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp...
-
11B-206.7.5 Existing site constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 11B-206.7.5 Existing site constraints....
-
11B-206.7.5 Existing site constraints
Platform lifts shall be permitted where existing exterior site constraints make use of a ramp or elevator infeasible. Advisory 11B-206.7.5 Existing site constraints....
-
11B-206.2.3.2 Distance to Elevators
new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via ramp...
-
1013.4 Raised character and braille exit signs
Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a tactile exit...
-
1017.10 Trailhead Signs
Typical and maximum running slope; and 5. Typical and maximum cross slope....
-
1017.10 Trailhead Signs
Typical and maximum running slope; and 5. Typical and maximum cross slope....
-
1014.3 Floor
This section requires the floor surface within camp shelters to be firm and stable and to slope not steeper than 1:48 in any direction....
-
11B-403.7 Continuous gradient
The slope of the resting area in all directions shall be 1:48 maximum. ETA Editor's Note CBC requirement 11B-403.7 is not present in the 2010 ADA Standards....
-
11B-403.7 Continuous gradient
The slope of the resting area in all directions shall be 1:48 maximum. ETA Editor's Note CBC requirement 11B-403.7 is not present in the 2010 ADA Standards....
-
11B-705.1.1.4 Resiliency
Exception: Detectable warning surfaces at curb ramps, islands or cut-through medians shall not be required to comply with Section 11B-705.1.1.4....
-
11B-705.1.1.4 Resiliency
Exception: Detectable warning surfaces at curb ramps, islands or cut-through medians shall not be required to comply with Section 11B-705.1.1.4....
-
1010.1.6 Thresholds
Raised thresholds and floor level changes greater than ¼ inch (6.4 mm) at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope...
-
1010.1.6 Thresholds
Raised thresholds and floor level changes greater than ¼ inch (6.4 mm) at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope...
-
11B-233.3.1.2.6.3 Test number two, site analysis test
Calculate the percentage of the total buildable area of the undisturbed site with a natural grade less than 10 percent slope....
-
11B-411.2.1.3.4 Position
Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane....
-
11B-411.2.1.3.4 Position
Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane....
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms,...
-
Gaps: ADA Standard Section 1002.4.3
EXCEPTION: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
-
General [4.5.1]
Many variables affect the performance of a given walking surface, including slope and cross slope, its material, jointing, texture, and finish, the presence of moisture or contaminants,...