With the Loop, audio signals are transmitted directly to your telecoil (T-coil) equipped hearing aid, broadcasting sound that is customized to your ears only....
Search Results "Elevator Hall Signal"
- Hearing Loop Systems T-Coil System
-
4.28.4* Auxiliary Alarms
a visual alarm connected to the building emergency alarm system or shall have a standard 110-volt electrical receptacle into which such an alarm can be connected and a means by which a signal...
-
Intensity
Intensity To be effective, a visual signal (or its reflection from adjacent walls and ceiling) must be of an intensity that will raise the overall light level sharply, but not be so intense...
-
Areas of Rescue Assistance [4.1.3(9), 4.3.11]
assistance are not required in alterations, non-occupiable spaces, open-air structures, or buildings equipped with "supervised automated sprinkler systems, “which are systems with built-in signals...
-
11B-411.2.2.2 Verbal identification
When the accessibility function button is pressed, verbal announcement of the car designation shall be provided at the elevator car entrance upon arrival....
-
11B-411.2.2.2 Verbal identification
When the accessibility function button is pressed, verbal announcement of the car designation shall be provided at the elevator car entrance upon arrival....
-
1.1.3.2, Item 14.1
Theater, dancehall, skating rink, auditorium, assembly hall, meeting hall, nightclub, fair building or similar place of assemblage where 50 or more persons may gather together in a building...
-
4.28.3(7)
(7) In general, no place in any room or space required to have a visual signal appliance shall be more than 50 ft (15 m) from the signal (in the horizontal plane)....
-
Audible Alarms [4.28.2]
Recommendation: Alarms with a periodic element to the signal, such as single stroke bells, hi-low, and fast whoop, are considered more effective than those with continuous or reverberating...
-
§1193.43(e) Availability of auditory information for people who are hard of hearing
., increased amplification, increased signal-to-noise ratio, or combination). For transmitted voice signals, provide a gain adjustable up to a minimum of 20 dB....
-
11B-706.1 General
For example, an FM system may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight....
-
Overview of Proposed Guidelines
surfaces; Pedestrian street crossings at roundabouts, including requirements for detectable edge treatments where pedestrian crossing is not intended, and pedestrian activated signals...
-
11B-706.1 General
For example, an FM system may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight....
-
1009.8.1 System requirements
The two-way communication system shall include both audible and visible signals. Systems shall be listed in accordance with UL 2525 and installed in accordance with NFPA 72....
- Brooks Equipment FIRETECH™ Fire Extinguisher Stand
- Estimote Sticker Beacons - Introducing Nearables
-
Compatible
Examples are teletypewriters (TTYs), visual signaling devices and amplifiers....
-
R104 Referenced Standards (Section-by-Section Analysis)
the relevant requirements regarding the provision of alternate pedestrian access routes when a pedestrian circulation path is temporarily closed, the provision of accessible pedestrian signals...
-
Two-Way Communication Systems [§230 and §708]
Communication Systems [§230 and §708] Where two-way communication systems are provided to gain entry to a facility or to restricted spaces, they must include visual and audible signals...
-
STAIR
A change in elevation, consisting of one or more risers....
-
STAIR
A change in elevation, consisting of one or more risers....
-
PLACE OF PUBLIC ACCOMMODATION
(2) A restaurant, bar, or other establishment serving food or drink; (3) A motion picture house, theater, concert hall, stadium, or other place of exhibition or entertainment;...
-
PLACE OF PUBLIC ACCOMMODATION
(2) A restaurant, bar, or other establishment serving food or drink; (3) A motion picture house, theater, concert hall, stadium, or other place of exhibition or entertainment;...
-
I. Security
Is the security latch or bolt on the hall door mounted no higher than 48" above the floor so it is within the reach of persons who use wheelchairs and is it operable with one hand, without...