The height of the clear floor or ground space is considered to be a volume from the floor to 80 inches (2030 mm) above the floor....
Search Results "Closer Height"
Commonly Searched Documents
-
407.2.1.3 Clear Floor or Ground Space
-
213.3.1 Toilet Compartments
Full-height partitions and door assemblies can comprise toilet compartments where the minimum required spaces are provided within the compartment....
-
A. Directional Signage
their background -- either light characters on a dark background or dark characters on a light background.” ix For a complete list of signage specifications including character height...
-
9.2* POST OFFICE LOBBIES
Letter drops shall be mounted at heights that comply with 4.2. (1) All fixed partitions must be installed to withstand a 250-pound force applied at any point and from any direction....
-
Van-Accessible Parking Spaces
accessible parking spaces for cars except for three features needed for vans: a wider access aisle (96") to accommodate a wheelchair lift; vertical clearance to accommodate van height...
-
Re: Section 307 Protruding Objects
object hazard based solely on section 307, but so is the (code compliant) lavatory with its (required) 29" high front edge, and the 8" deep (code compliant) shelf mounted at the (required) height...
-
Entrances
Additionally, the door hardware must not require tight grasping, pinching, or twisting, and the height of the door threshold must not be greater than ½ inch....
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The technical requirements address clear floor space, height, faucets, and exposed pipes and surfaces....
-
Accessible Slopes
That means for every inch of height change there should be at least 12 inches of ramp run....
-
Lift Compatibility (M301.4 and M302.4)
A patient lift may be the only means of providing access to certain equipment that cannot meet the technical criteria for transfer surface height (see M301.2.1 and M302.2.1) because of the...
-
[A] ALTERATION
resurfacing of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height...
-
Reach Range
Accessible reach ranges specify a minimum height of 15 inches (308.3) for unobstructed reaches....
-
606 Lavatories and Sinks
These specifications concern clear floor space requirements (606.2, Exception 3) and heights (606.3, Exception 2)....
-
608.3 Grab Bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor. EXCEPTIONS: 1....
-
Physical Barriers
For example, is there an adjustable height examining table? Equipment or aids....
-
608.3 Grab Bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor. EXCEPTIONS: 1....
-
Passenger Loading Zones [4.6.6]
Where aisles are flush with the pull-up space, wheelchair transfer is easier (the change in level of aisles at curb height can make transfer very difficult)....
-
703.3.1 Dimensions and Capitalization
0.090 (2.3 mm) to 0.100 (2.5 mm) Distance between corresponding dots in adjacent cells¹ 0.241 (6.1mm) to 0.300 (7.6mm) Dot height...
-
4.34.6.7* OVENS
Ovens shall be of the self-cleaning type or be located adjacent to an adjustable height counter with knee space below (see Fig. 52)....
-
1.1.12 Ramp cross slope
A simple method of establishing the relative elevations of the top and bottom of each ramp is to use a rotating laser level on a tripod and document the difference in height on a stiff metal...
-
[A] ALTERATION
resurfacing of circulation paths or vehicular ways, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls and full-height...
-
11B-607.6 Shower spray unit and water
If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars....
-
11B-604.8.1.5 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped grab bar meeting the dimensional requirements of Sections 11B-604.5.1 and 11B-604.5.2 shall...
-
11B-233.3.1.2.6.5 Additional requirements.
Water closet seat height complying with Section 11B-809.10.7.4. 7. Electrical receptacles, switches and controls complying with Section 11B-809.12. 8....