The Model O is Roximity's newest beacon. It’s tiny, inexpensive, and powerful. Small, Really Small - ROXIMITY’s Model O is tiny. So tiny you can make them part of your...
Search Results "Fixed Route System"
Commonly Searched Documents
- ROXIMITY's Model O iBeacon
- Allen Tel ADA Outdoor Phone with Amplified Receiver and No Dial - No Housing
- inLOOP Personal Loop 400
- Allen Tel ADA Outdoor Disability Speakerphone Single Number Dial
- Allen Tel Emergency Phone Automatic Ring Down - No Dial
- Allen Tel Emergency Phone Automatic Ring Down Circuit - Single Number Dial
- Allen Tel ADA Outdoor Phone with Amplified Receiver and No Dial
- Signaids Floor Numbering and Stair Shaft Designation-Style 2
- Signaids Floor Numbering and Stair Shaft Designation-Style 1
- Allen Tel ADA Outdoor No Dial Phone with Speakerphone
- ROXIMITY's Model X iBeacon
-
Running Slope [1016.7.1]
Table 3—Maximum Running Slope and Segment Length Running Slope of Segment of Outdoor Recreation Access Route Maximum Length of Segment Steeper Than But Not...
-
Egress [4.1.3(9), 4.3.10]
Otherwise, in new construction, ADAAG requires areas of rescue assistance unless the building is equipped with a supervised automated sprinkler system....
-
Sec.36.308(a)(1)(ii)(C)
(C) Adjoin an accessible route that also serves as a means of egress in case of emergency; and...
-
Outdoor Recreation Access Routes in Viewing Areas [F246.4]
At viewing areas not located along trails, at least one ORAR must connect accessible parking spaces or other arrival points that serve the viewing area with accessible elements,...
-
F202.6.5.5 Assembly Areas
Assistive listening systems shall comply with F219 and assembly seating shall comply with F221....
-
1003.2.13.3 Elevators
Elevators are not required to be accessed from an area of refuge or horizontal exit in buildings and facilities equipped throughout with an automatic sprinkler system installed in accordance...
-
1018.8 Resting Intervals
Resting intervals shall comply with 1018.8.
-
1018.8.1 Size
Resting intervals shall be 60 inches minimum (1525 mm) by 60 inches (1525 mm) minimum.
-
Section 2. Vehicular or pedestrian arrival points
"Vehicular or pedestrian arrival points" means public or resident parking areas, public transportation stops, passenger loading zones, and public streets or sidewalks.
-
2.10 Gates and Barriers
Where gates or barriers are constructed to control access to an ORAR, gates and barriers shall comply with 2.10.
-
2.8 Openings
Openings in the surface of ORARs shall be small enough to prevent passage of a 1/2 inch (13 mm) diameter sphere. Where possible, elongated openings should be placed...
-
6.8 Resting Intervals
Resting intervals shall comply with 6.8.
-
6.8.1 Size
The resting interval length shall be a minimum of 60 inches (1525 mm) long by 60 inches (1525 mm) wide.