5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25 inches....
Search Results "Extended Floor Surface"
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
- Pilot Rock ASW-20 Series Grill
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
5.2.1.4 Transfer Surface Size for Imaging Equipment. The transfer surface should be 28 inches wide minimum and 21 inches deep minimum....
-
What kinds of treatments constitute maintenance rather than an alteration?
Treatments that serve solely to seal and protect the road surface, improve friction, and control splash and spray are considered to be maintenance because they do not significantly affect...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
4.15.5(1)
(1) Wall- and post-mounted cantilevered units shall have a clear knee space between the bottom of the apron and the floor or ground at least 27 in (685 mm) high, 30 in (760 mm) wide, and...
-
Single-User Toilet Rooms: No Side Transfer Space
Single-User Toilet Rooms: No Side Transfer Space On single plumbing walls, lavatories can overlap water closet clear floor space although this precludes side transfers....
-
11B-233.3.1.2.2 Non-elevator buildings
Ground floor residential dwelling units in non-elevator buildings shall be adaptable....
-
11B-233.3.1.2.2 Non-elevator buildings
Ground floor residential dwelling units in non-elevator buildings shall be adaptable....
-
11B-813.2.9 Overlap
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap....
-
1016.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
2.4.2 Cross Slope
Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48 (2 percent). ...
-
1016.7.2 Cross Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1018.8.2 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
M302.2.2 Size
The transfer surface shall be 21 inches (610 mm) wide minimum and 15 inches (381 mm) deep minimum. Advisory M302.2.2 Size....
- Carr Corporation Folding Work Desk/Charting Stations
-
1011.2.3 Slope
Where the surface is other than asphalt, concrete, or boards, slopes not steeper than 1:20 are permitted when necessary for drainage....
-
1016.7.2 Cross Slope
Where the surface is other than asphalt, concrete, or boards, cross slopes not steeper than 1:20 are permitted when necessary for drainage....
-
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302 The Committee recommends adjustable height in small, virtually continuous increments....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
1018.8.2 Slope
EXCEPTION: Where the surface is other than concrete, asphalt, or boards, cross slopes not steeper than 1:20 shall be permitted when necessary for drainage....
-
M302.2.5 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as they...
-
§ 38.57(c)
(c) The diameter or width of the gripping surface of handrails and stanchions shall be 11/4 inches to 11/2 inches or provide an equivalent gripping surface and shall provide a minimum 11...
-
4.3.3 Slope
When the surface is not paved or is not elevated above the natural ground, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...