Turning Space [§304] Turning space is required in these accessible rooms and spaces: toilet and bathing facilities dressing, fitting, and locker rooms transient...
Search Results "Wheelchair Seating Space"
-
Turning Space [§304]
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
Bus Shelter Benches
Don't you think that's because 903 benches are designed for wheelchair users to transfer onto them and that's not expected to be necessary at bus shelter benches? ...
-
703.5.8 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
5.1 GENERAL
In addition to the requirements of 4.1 to 4.33, the design of at least 5 percent of all fixed seating or tables in a restaurant or cafeteria shall comply with 4.32....
-
3. Desk clear floor space
Desk clear floor space: If provided, desks and writing tables need to have a 30-inch by 48-inch clear floor space that extends 19 inches under the desk and any fixed seat needs to be removable...
- Figure 1009.2.4 Pool Lift Seat Height – Drawing from the U.S. Access Board
-
Wheelchair Transfer
Wheelchair Transfer The manner of approach and transfer to water closets varies among people with disabilities....
-
Armrests M302.3.2
Armrests M302.3.2 Armrests are recommended but not required. If provided armrests cannot interfere with transfer supports during the transfer. Dual transfer support/armrest...
-
§ 36.302(f)(9) Purchasing multiple tickets
(9) Purchasing multiple tickets.
-
R403.2 Clear Space
R403.2 Clear Space. A clear space complying with R404 shall be provided at operable parts....
-
General [5.1]/ Access Aisles [5.3]
Space should also be available so that people using wheelchairs do not obstruct required exit and circulation routes....
-
E202.4 Functions Located in Maintenance or Monitoring Spaces (Section-by-Section Analysis)
E202.4 Functions Located in Maintenance or Monitoring Spaces (Section-by-Section Analysis) This section proposes to revise § 1194.3(f) of the existing 508 Standards to clarify that, where...
-
4.27.2 Clear Floor Space
Clear floor space complying with 4.2.4 that allows a forward or a parallel approach by a person using a wheelchair shall be provided at controls, dispensers, receptacles, and other operable...
-
4.27.2 CLEAR FLOOR SPACE
Clear floor space complying with 4.2.4 that allows a forward or a parallel approach by a person using a wheelchair shall be provided at controls, dispensers, receptacles, and other operable...
-
§382.57(c)(2) Clear floor or ground space
(2) Clear floor or ground space. A clear floor or ground space complying with section 305 of the U.S....
-
Maneuvering Space Where Ramps are Provided
Maneuvering Space Where Ramps are Provided At least one maneuvering space must be provided on the same level as the play component....
-
§ 38.53(a)(2)
(2) If doorways connecting adjoining cars in a multi-car train are provided, and if such doorway is connected by an aisle with a minimum clear width of 30 inches to one or more spaces where...
-
5.4.3 Transfer Support Height for M301 and M302
would be an appropriate height for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
11B-502 Parking spaces
[See subsections ...]
-
11B-502 Parking spaces
[See subsections ...]