Clear floor space: Adequate space is provided to approach the toilet from a variety of wheelchair transfer positions (i.e. diagonal or side approaches)....
Search Results "Wheelchair Seating Space"
-
6. Clear floor space
-
Turning Space [§304]
Turning Space [§304] Turning space is required in these accessible rooms and spaces: toilet and bathing facilities dressing, fitting, and locker rooms transient...
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
703.5.8 Character Spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces....
-
5.1 GENERAL
In addition to the requirements of 4.1 to 4.33, the design of at least 5 percent of all fixed seating or tables in a restaurant or cafeteria shall comply with 4.32....
-
3. Desk clear floor space
Desk clear floor space: If provided, desks and writing tables need to have a 30-inch by 48-inch clear floor space that extends 19 inches under the desk and any fixed seat needs to be removable...
- Figure 1009.2.4 Pool Lift Seat Height – Drawing from the U.S. Access Board
-
Wheelchair Transfer
Wheelchair Transfer The manner of approach and transfer to water closets varies among people with disabilities....
-
Armrests M302.3.2
Armrests M302.3.2 Armrests are recommended but not required. If provided armrests cannot interfere with transfer supports during the transfer. Dual transfer support/armrest...
-
§ 36.302(f)(9) Purchasing multiple tickets
(9) Purchasing multiple tickets.
-
R403.2 Clear Space
R403.2 Clear Space. A clear space complying with R404 shall be provided at operable parts....
-
General [5.1]/ Access Aisles [5.3]
Space should also be available so that people using wheelchairs do not obstruct required exit and circulation routes....
-
E202.4 Functions Located in Maintenance or Monitoring Spaces (Section-by-Section Analysis)
E202.4 Functions Located in Maintenance or Monitoring Spaces (Section-by-Section Analysis) This section proposes to revise § 1194.3(f) of the existing 508 Standards to clarify that, where...
-
4.27.2 Clear Floor Space
Clear floor space complying with 4.2.4 that allows a forward or a parallel approach by a person using a wheelchair shall be provided at controls, dispensers, receptacles, and other operable...
-
4.27.2 CLEAR FLOOR SPACE
Clear floor space complying with 4.2.4 that allows a forward or a parallel approach by a person using a wheelchair shall be provided at controls, dispensers, receptacles, and other operable...
-
§382.57(c)(2) Clear floor or ground space
(2) Clear floor or ground space. A clear floor or ground space complying with section 305 of the U.S....
-
Maneuvering Space Where Ramps are Provided
Maneuvering Space Where Ramps are Provided At least one maneuvering space must be provided on the same level as the play component....
-
§ 38.53(a)(2)
(2) If doorways connecting adjoining cars in a multi-car train are provided, and if such doorway is connected by an aisle with a minimum clear width of 30 inches to one or more spaces where...
-
5.4.3 Transfer Support Height for M301 and M302
would be an appropriate height for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying position, and diagnostic equipment used by patients in a seated...
-
11B-502 Parking spaces
[See subsections ...]
-
11B-502 Parking spaces
[See subsections ...]