Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
Search Results "Unit of Measurement"
Commonly Searched Documents
-
604.8.1.1 Size
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
-
D. Election Day Compliance Review
In the materials provided to each Election Judge for Election Day, the County will include a checklist of the temporary measures to be implemented on Election Day at each...
- Bradley 643 Standard Series Horizontal Recessed Soap Dispenser
-
703.3.1 Dimensions and Capitalization
Table 703.3.1 Braille Dimensions MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES Dot base diameter 0.059...
-
1.2.6
1.2.6 When local variations (flatness) in running slope of ramps are measured according to 1.1.13 at least 80% (rounded to the nearest whole number) of the measurements should not exceed...
- Schumacher Elevator Company: Virtual Plant Tour in HD by SAPTV
-
608.2.2 Standard Roll-In Type Shower Compartments
Standard roll-in type shower compartments shall be 30 inches (760 mm) wide minimum by 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides...
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
M302.4.2 Clearance Around Base
The base of the diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination...
-
12112(b)(7)
impairs sensory, manual, or speaking skills, such test results accurately reflect the skills, aptitude, or whatever other factor of such applicant or employee that such test purports to measure...
-
D. Tools Needed
Tools Needed The following items are needed for the survey: A metal tape measure that is at least 20 feet long; A digital level or bubble level that is 24 inches long...
-
§104.13(b)
that impairs sensory, manual, or speaking skills, the test results accurately reflect the applicant's or employee's job skills, aptitude, or whatever other factor the test purports to measure...
-
12112(b)(7)
impairs sensory, manual, or speaking skills, such test results accurately reflect the skills, aptitude, or whatever other factor of such applicant or employee that such test purports to measure...
-
Verify Electrical
Measure to top or bottom of boxes 11B-308.1.1 Heights of all electrical switch boxes....
-
Verify Electrical
Measure to top or bottom of boxes 11B-308.1.1 Heights of all electrical switch boxes....
-
Plumbed Fixtures
Plumbed Fixtures ADAAG covers fixed units where they are provided. Fixed units are not required over units that are not fixed....
-
Section 36.406(c) Places of Lodging
Lock-off units are units that are multi-bedroom but can be “locked off’’ into two separate units, each having individual external access....
-
What Testing Accommodations Must Be Provided?
entities must ensure that the test scores of individuals with disabilities accurately reflect the individual’s aptitude or achievement level or whatever skill the exam or test is intended to measure...
-
1630.11 Administration of tests
that impairs sensory, manual or speaking skills, the test results accurately reflect the skills, aptitude, or whatever other factor of the applicant or employee that the test purports to measure...