Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
Search Results "Perpendicular Curb Ramp"
-
11B-608.1 General
-
§35.150 Existing facilities (Section-by-Section Analysis)
ramps or other sloped areas at any intersection having curbs or other barriers to entry from a street level pedestrian walkway, and all newly constructed or altered street level pedestrian...
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
11B-308.3.2 Obstructed high reach
Operable parts of fuel dispensers shall be permitted to be 54 inches (1372 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
Elevated Play Components
Play areas with 20 or more elevated components must use ramps to connect a minimum of 25 percent of those components. ...
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
1007 Miniature Golf Facilities
covers miniature golf courses and contains specifications for accessible routes that take into account design conventions for miniature golf courses, such as carpeted play surfaces and curbs...
-
Side Reach [§308.3]
Fuel Dispensers The operable parts of fuel dispensers located on existing curbs can be up to 54” high....
-
Handrails Along Walkways
The 1991 Standards do not contain any technical requirement for handrails provided along walkways that are not ramps....
-
R409.4 Height
Top of gripping surfaces of handrails shall be 865 mm (2.8 ft) minimum and 965 mm (3.2 ft) maximum vertically above walking surfaces, ramp surfaces, and stair nosings....
-
1133B.5.4.5
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.5 Ramps. 1133B.5.4.5 Landing width. ...
-
EXIT
Exit components include exterior exit doors at the level of exit discharge, interior exit stairways, interior exit ramps, exit passageways, exterior exit stairways and exterior exit ramps...
-
11B-604.3.2 Overlap
26 inches (660 mm) minimum from the water closet centerline to allow for the installation of a grab bar where the clearance at the water closet is 66 inches (1676 mm) minimum measured perpendicular...
-
11B-604.3.2 Overlap
26 inches (660 mm) minimum from the water closet centerline to allow for the installation of a grab bar where the clearance at the water closet is 66 inches (1676 mm) minimum measured perpendicular...
-
404.2.4.2 Doorways without Doors or Gates
Maneuvering Clearances at Doorways without Doors or Gates, Manual Sliding Doors, and Manual Folding Doors Minimum Maneuvering Clearance Approach Direction Perpendicular...
-
404.2.4.2 Doorways without Doors or Gates
Doorways without Doors or Gates, Manual Sliding Doors, and Manual Folding Doors Minimum Maneuvering Clearance Approach Direction Perpendicular...
-
4.34.3(2)(b) Reach Depth More Than 10 in
Where the reach depth to the operable parts of any control as measured from the vertical plane perpendicular to the edge of the unobstructed clear floor space at the farthest protrusion...
-
11B-604.8.1.2 Doors
that if the approach is from the push side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 48 inches (1219 mm) minimum measured perpendicular...
-
11B-604.8.1.2 Doors
that if the approach is from the push side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 48 inches (1219 mm) minimum measured perpendicular...
-
Scoping [4.1.3(5)]
In new construction, platform lifts can be used instead of ramps or elevators only in providing access to: performing areas in assembly occupancies wheelchair seating locations...
-
Accessible Teeing Grounds, Putting Greens, and Weather Shelters
Section 1006.3.2 of the 2010 Standards requires that where curbs or other constructed barriers prevent golf cars from entering a fairway, openings 60 inches wide minimum shall be provided...
-
1127B.1
be designed to provide access to all entrances and exterior ground floor exits, and access to normal paths of travel, and where necessary to provide access, shall incorporate pedestrian ramps...