The Guidelines for Requirement 1 present guidance on designing an accessible entrance on an accessible route, as required by §100.205(a), and on determining when an accessible...
Search Results "Ground Surface"
-
Guidelines for Requirement 1
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-805.7 Built-in cabinets and work surfaces
Built-in cabinets, counters and work surfaces shall be accessible, including: patient wardrobes, nurse’s stations, administrative centers, reception desks, medicine preparation areas, laboratory...
-
Clear Floor or Ground Space: ADA Standard Section 805.3
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed.
-
10.4.1(5)
Gates which must be pushed open by wheelchair or mobility aid users shall have a smooth continuous surface extending from 2 inches above the floor to 27 inches above the floor....
-
Features of Accessible Parking Spaces
Parking space identification sign with the international symbol of accessibility complying with 703.7.2.1 mounted 60 inches minimum above the ground surface measured to the bottom of the...
-
5.3.3.1 Transfer Sides Recommendation for Exam Chairs with Fixed Footrests
The Committee recommends exam chairs with a fixed footrest have a transfer surface minimum of a 17 inch depth and a 21 inch width located on both sides of the chair to allow for a left or...
- Lynx Grills Inc. 30” Grill ProSear Burner & 1 Stainless Steel Burner (L500ADA)
-
M301.2.1 Height
The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor to the top of the transfer surface....
- Humanscale Float Height-Adjustable Table
- Electrolux Icon 36" Freestanding Full-Gas Range
- Mockett TLRAL27 Roma Series Adjustable Table Leg
-
Diversified Woodcrafts Mobile Lab Station with flat top 4352KF
ADA Compatible Mobile Lab Perfect for the physically impaired or for classroom demos. Constructed of solid oak, hardwood and oak veneers with a chemical resistant, earth-friendly...
- Lynx Grills Inc. 36” Grill - 1 ProSear Burner & 2 Stainless Steel Burners (L600ADA)
-
1.1.9 Horizontal gaps and vertical alignment
horizontal discontinuities and variations in vertical alignment such as at concrete joints, gaps, grade breaks, and at the interface of concrete with other materials or elements built into the surface...
-
Diversified Woodcrafts Oak Table with Book Compartments 24x48
Warranty Made in the USA Manufactured with 2 book compartments measuring 14"W x 13-5/8"D x 3-7/8"H Minimal assembly required; legs need to be attached No Table Surface...
- Lynx Grills Inc. 36” Grill 1 ProSear Burner & 2 Stainless Steel Burners with Rotisserie (L600ADAR)
- Lynx Grills Inc. 30” Grill 1 ProSear Burner & 1 Stainless Steel Burner with Rotisserie (L500ADAR)
-
11B-805.7 Built-in cabinets and work surfaces
Built-in cabinets, counters and work surfaces shall be accessible, including: patient wardrobes, nurse’s stations, administrative centers, reception desks, medicine preparation areas, laboratory...
-
Addendum D: Comparison of demographics and transfer height between Phase 1 and Phase 2 of the study
[See subsections ...]
-
4.3.7 Slope
An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route exceed 1:50.
-
4.3.7 SLOPE
An accessible route with a running slope greater than 1:20 is a ramp and shall comply with 4.8. Nowhere shall the cross slope of an accessible route exceed 1:50.
-
Electronic instruments
Electronic instruments have been developed to measure floor flatness. Originally created to measure the flatness of concrete floors in critical applications such as narrow - aisle...