In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support visible...
Search Results "Visible Signal (Elevator Landing)"
Commonly Searched Documents
-
907.5.2.3.3 Group R-2
-
Mounting Height
Mounting Height ADAAG specifies a signal height 80 inches above the highest floor level within the space or 6 inches below the ceiling, whichever is lower....
-
Protruding Objects [§204]
Circulation paths include interior and exterior walks, paths, hallways, courtyards, elevators, platform lifts, ramps, stairways, and landings. Examples of Protruding Objects...
-
Audible and Visual Indicators: ADA Standard Section 708.2
The system shall provide both audible and visual signals. Advisory 708.2 Audible and Visual Indicators. A light can be used to indicate visually that assistance is on the way....
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
-
11B-708.2 Audible and visual indicators
The system shall provide both audible and visual signals. Advisory 11B-708.2 Audible and visual indicators. A light can be used to indicate visually that assistance is on the way....
-
UNITED STATES OF AMERICA v. METROPOLITAN TRANSPORTATION AUTHORITY and NEW YORK CITY TRANSIT AUTHORITY - OPINION & ORDER
UNITED STATES DISTRICT COURT SOUTHERN DISTRICT OF NEW YORK BRONX INDEPENDENT LIVING SERVICES, a nonprofit organization; DISABLED IN ACTION OF METROPOLIAN NEW YORK, a nonprofit...
- EZCurb Ramp - Vertical Barrier Removal Instructional Video
- NYC Board of Elections: Video 6 - Verifying Temporary Solutions
-
RISER
[DSA-AC] The upright part between two adjacent stair treads, between either an upper or lower landing and an adjacent stair tread, or between two adjacent landings....
-
1009.3.3 Area of Refuge
Stairways shall either incorporate an area of refuge within an enlarged floor-level landing or shall be accessed from an area of refuge complying with Section 1009.6....
-
Submerged Depth: ADA Standard Section 1009.3.2
Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
11B-1009.3.2 Submerged depth
Where landings are required by Section 11B-405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
Section 504
Accessibility Standards for compliance with Title II of the ADA, Education permitted entities subject to our Section 504 regulation and the ADA to use the 1991 Standards, except that the elevator...
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
- BEA Inc. Magic Switch Hardwired Touchless Sensor Door Opener MS21H (Wave to Open)
-
907.5.2.3.1 Public use areas and common use areas
Visible alarm notification appliances shall be provided in public use areas and common use area, including but not limited to: Band rooms Classrooms Corridors Gymnasiums Lobbies...
-
1023.9 Stairway identification signs
A sign shall be provided at each floor landing in an interior exit stairway and ramp connecting more than three stories designating the floor level, the terminus of the top and bottom of...
-
When Ramps Are Required
When Ramps Are Required Ramps are required on composite structures with 20 or more elevated play components and must connect to at least 25 percent of the elevated play components. ...
-
3.4 Staff-Related Barriers and Solutions
Barriers Solutions Simple/Low cost Involved / High cost Staff is hard to find when you need help Work out a signal with one or...
-
General: ADA Standard Section 706.1
For example, an FM system may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight....
-
11B-505.10.1 Top and bottom extension at ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
8. Can an elevated crawl tube be used to connect to a play component required to be accessible? Can that crawl tube also be considered an accessible play component?
Can an elevated crawl tube be used to connect to a play component required to be accessible? Can that crawl tube also be considered an accessible play component?...