Floor or ground surfaces of curb ramps and blended transitions shall comply with Section 11B-405.4....
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
-
11B-406.5.4 Floor or ground surfaces
-
11B-406.5.4 Floor or ground surfaces
Floor or ground surfaces of curb ramps and blended transitions shall comply with Section 11B-405.4....
- Access-Able Designs Wall Mounted Shower Transfer Bench SH-400
- Gamco Reversible Hand Folding Shower Seat ADA, Ivory Phenolic - 5181
-
810.5.3 Platform and Vehicle Floor Coordination--Modification to 810.5.3 of Appendix D to 36 CFR Part 1191
810.5.3 Platform and Vehicle Floor Coordination--Modification to 810.5.3 of Appendix D to 36 CFR Part 1191 Station platforms shall be positioned to coordinate with vehicles in accordance...
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
Accessible Parking Space Width
The proposed rule specified that car and van spaces be at least 8 feet wide and that access aisles be at least 5 feet wide for car spaces and at least 8 feet wide for van spaces....
-
106.5.63 Space
A definable area, such as a room, toilet room, hall, assembly area, entrance, storage room, alcove, courtyard, or lobby.
-
Turn Space
60-inch (1525mm) Diameter Space T-Shaped Space for 180 Degree Turns...
-
11B-703.8.8 Line spacing
Low resolution VMS characters shall comply with Section 11B-703.5.9.
-
4.26.3 STRUCTURAL STRENGTH
The structural strength of grab bars, tub and shower seats, fasteners, and mounting devices shall meet the following specification: (1) Bending stress in a grab bar or seat induced by...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep maneuvering space...
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device,...
-
610.4 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device,...
-
610.4 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device,...
-
11. Gap
11. Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so...
-
610.4 Structural Strength
610.4 Structural Strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat,...
-
11B-610.4 Structural strength
11B-610.4 Structural strength. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the...
-
11B-610.4 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device,...
- Symmons Temptrol II (2000 Series) Tub/Shower Mixing Valve 15-2
- Delta Adjustable Grab Bar 2-Setting Hand Shower 52001-UF
- Delta Adjustable Grab Bar 2-Setting Hand Shower 52003-UF
-
Kitchen Counters, Walls, and Floors
Light colored counters and floors throughout to increase reflected light and save energy....