Buttons with floor designations shall be provided with visible indicators to show that a call has been registered....
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
-
11B-407.4.7.1.4 Visible indicators
-
180 Turns Around Obstructions
The clear width must be at least 48” at the turn and 42” minimum approaching the turn (unless the clear width at the turn is 60” minimum)....
-
R410.10 Line Spacing
R410.10 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
Side Entry: ADA Standard Section 1002.4.4.2
The amount of clear space needed within the ride, and the size and position of the opening are interrelated....
-
502.3 Access Aisle
Access aisles serving parking spaces shall comply with 502.3. Access aisles shall adjoin an accessible route. Two parking spaces shall be permitted to share a common access aisle....
- Delta Single Function Hand Shower with Grab Bar and Elbow RPW324HDF
- Delta Single Function Hand Shower With Grab Bar and Elbow RPW336HDF
-
11B-224.2 Guest rooms with mobility features
In transient lodging facilities, guest rooms with mobility features complying with Section 11B-806.2 shall be provided in accordance with Table 11B-224.2, as follows. [2010 ADAS]...
-
11B-224.2 Guest rooms with mobility features
In transient lodging facilities, guest rooms with mobility features complying with Section 11B-806.2 shall be provided in accordance with Table 11B-224.2, as follows. [2010 ADAS]...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
-
Accessibility
Accessibility: When ceramic tile is used as the flooring surface, design professionals should consider the following, based on ANSI A108.01 and A108.02, where accessibility is a primary...
-
4.3.5.3 180-degree turn around an obstacle
In effect, this condition is a space bounded by three sides and requires a lot more space because WhMD users cannot cut the corner like they can with a wider aisle width (Figure 4‒6)....
-
R203 Machinery Spaces (Section-by-Section Analysis)
R203 Machinery Spaces (Section-by-Section Analysis) Vaults, tunnels, and other spaces used by service personnel only are not required to comply with the proposed guidelines....
-
Extended Floor or Ground Surface: ADA Standard Section 405.9.1
Section 405.9.1 covers the current ADA Standards for extended floor or ground surface of the ramp run or landing.
- American Specialties Compact Rectangular Phenolic Fold-Up Shower Seat 8203
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture. In locations where toilets are adjacent to walls or bathtubs,...
-
809.2.2 Turning Space
EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm) maximum in depth or width. Advisory 809.2.2 Turning Space....
-
R302.3 Continuous Width
Clear width requirements are contained in R304.5.1 for curb ramps and blended transitions, and in R407.4 for ramps....
-
11B-807.2.1 Turning space
Turning space complying with Section 11B-304 shall be provided within the cell....
-
11B-806.2.6 Turning space
Turning space complying with Section 11B-304 shall be provided within the guest room....
-
802.1 Wheelchair Spaces
Wheelchair spaces shall comply with 802.1....
-
106.5.77 Wheelchair Space
Space for a single wheelchair and its occupant....
-
802.1 Wheelchair Spaces
Wheelchair spaces shall comply with 802.1....