Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use...
Search Results "Viewing Location"
-
11B-608.3 Grab bars
-
11B-608.5.2 Standard roll-in type shower compartments
and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located...
-
11B-608.3 Grab bars
Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use...
-
Designated Aisle Seats
At least five percent (5%) of the aisle seats are required to be designated aisle seats and to be located closest to accessible routes....
-
For People with Disabilities, Which Circulation Paths Are Usable, Available, and Closest?
Exits should be marked by tactile signs that are properly located so they can be readily found by a person who is blind or has low vision from any direction of approach to the exit access...
-
11B-608.5.3 Alternate roll-in type shower compartments
and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located...
-
Structural Impracticability (Preamble, Section-by-Section Analysis)
A situation in which a building must be built on stilts because of its location in marshlands or over water is an example of one of the few situations in which the exception for structural...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. #28)
estimated that single-user toilet rooms with out-swinging doors would be used slightly less than once every other visit to a facility with such toilet rooms covered by the final rules (or, viewed...
-
Structural Impracticability (Section-By-Section Analysis and Response to Comments)
A situation in which a building must be built on stilts because of its location in marshlands or over water is an example of one of the few situations in which the exception for structural...
-
ACTIONS TO BE TAKEN BY AURORA
disability, including HIV or AIDS, in the full and equal enjoyment of the goods, services, facilities, privileges, advantages, or accommodations offered at any of its current or future locations...
-
General description of monetized benefits for water closet clearance in single-user toilet rooms—out-swinging doors (Req. # 28)
estimated that single-user toilet rooms with out-swinging doors would be used slightly less than once every other visit to a facility with such toilet rooms covered by the final rules (or, viewed...
-
A. Accessible Voting Program
accessible on Election Day, or will relocate those locations to an alternative accessible location pursuant to the process established in Paragraph 17 of this Agreement....
- BEA Inc. PBJMS Series Jamb Push Plate (Push to Open)
- Kompan, Inc. Electronic Playgrounds ICON1012 Space
- Allen Tel Emergency Phone Automatic Ring Down - No Dial
- Allen Tel Emergency Phone Automatic Ring Down Circuit - Single Number Dial
- Takeform Fusion Signage Office/Suite/Room Identification Type I
- Takeform Fusion Signage Office/Suite/Room Identification Type H
-
11B-809.10.7.1 Floor space
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a...
-
1009.4.2 Area of refuge
Areas of refuge are not required at elevators not required to be located in a shaft in accordance with Section 712....
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-809.10.7.1 Floor space
Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) minimum for lavatories, cabinets, wing walls, or privacy walls located immediately adjacent to a...
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
Ramps
Provide handrails on each side of the ramps at the following locations:...