Such wheelchair spaces shall not reduce the means of egress minimum width or required capacity....
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
1009.6.3 Size
-
11B-304.3 Size
Turning space shall comply with Section 11B-304.3.1 or 11B-304.3.2....
-
11B-703.5.6 Height from finish floor or ground
11B-703.5.6 Height from finish floor or ground. Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1....
-
Carpet [§302.2]
Exposed edges must have trim on the entire length of the exposed edge and be fastened to the floor to prevent curling....
-
11B-303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with Section 11B-303....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
above the floor or ground surface of the wheelchair space....
-
203 General Exceptions
203 General Exceptions Limited Access Spaces and Machinery Spaces....
-
Surface and Clear Tread Width on Beach Access Routes
A beach access route must have a firm, stable surface, and have a clear tread width of 60 inches (1,525 millimeters) minimum....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
above the floor or ground surface of the wheelchair space....
-
1009.7.1 Size
Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1009.6.3....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
above the floor or ground surface of the wheelchair space....
-
A4.2.3 Wheelchair Turning Space
These guidelines specify a minimum space of 60 in (1525 mm) diameter or a 60 in by 60 in (1525 mm by 1525 mm) T-shaped space for a pivoting 180-degree turn of a wheelchair....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1. ...
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302. Changes in level are not permitted. Exceptions: 1....
-
M. Turning Space
M. Is there an area in each public restroom in which a person who uses a wheelchair can turn around - either a 60" diameter circle or a "T"-shaped turn area as shown in Figure 3...
-
4.5.4 Gratings
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g))....
-
4.5.4 GRATINGS
If gratings are located in walking surfaces, then they shall have spaces no greater than 1/2 in (13 mm) wide in one direction (see Fig. 8(g))....
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground....
-
A4.5.3 Carpet
When both carpet and padding are used, it is desirable to have minimum movement (preferably none) between the floor and the pad and the pad and the carpet which would allow the carpet to...
-
A4.2.3 WHEELCHAIR TURNING SPACE
This standard specifies a minimum space of 60 in (1525 mm) diameter for a pivoting 180-degree turn of a wheelchair....
-
M303.2.3 Wheelchair Spaces / Depth of Wheelchair Spaces for front or Rear Entry
M303.2.3 Wheelchair Spaces / Depth of Wheelchair Spaces for front or Rear Entry • Sub-Committee Recommendation: The Sub-committee and Full Committee have decided not to act on the proposed...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. ...
-
Diversified Woodcrafts Mobile Lab Station with flat top 4352KF
ADA Compatible Mobile Lab Perfect for the physically impaired or for classroom demos. Constructed of solid oak, hardwood and oak veneers with a chemical resistant, earth-friendly...
-
407.2.3.1 Floor Designation
407.2.3.1 Floor Designation. Floor designations complying with 703.2 and 703.4.1 shall be provided on both jambs of elevator hoistway entrances....