Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 and 11B-802....
Search Results "Urinal Clear Floor Space"
-
11B-206.7.2 Wheelchair spaces
-
Accessible Parking Space Width
The proposed rule specified that car and van spaces be at least 8 feet wide and that access aisles be at least 5 feet wide for car spaces and at least 8 feet wide for van spaces....
-
11B-608.9 Shower floor or ground surface
11B-608.9 Shower floor or ground surface. Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Turn Space
60-inch (1525mm) Diameter Space T-Shaped Space for 180 Degree Turns...
-
11B-703.8.8 Line spacing
Low resolution VMS characters shall comply with Section 11B-703.5.9.
-
11B-703.8.8 Line spacing
Low resolution VMS characters shall comply with Section 11B-703.5.9.
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
Inpro Corporation JointMaster® 787 Series Floor Expansion Joint Covers
Requires the Premium User plan or above. (Login or upgrade your account!)
-
F213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal....
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal....
-
1017.2 Aisles in assembly spaces
1017.2 Aisles in assembly spaces. Aisles and aisle accessways serving a room or space used for assembly purposes shall comply with Section 1028....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep maneuvering space...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep maneuvering space...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load served...
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
11B-812.7 Access aisle
Two vehicle spaces or one parking space and one electric vehicle charging space shall be permitted to share a common access aisle....
-
11B-812.7 Access aisle
Two vehicle spaces or one parking space and one electric vehicle charging space shall be permitted to share a common access aisle....
-
Tenant Spaces: ADA Standard Section 206.4.5
Section 206.4.5 covers scoping requirements in the most current ADA Standards for accessible routes to Ttenant spaces.
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal....
-
11B-408.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....