Where spectators are expected to stand during events, spectators in wheelchair spaces shall be afforded lines of sight complying with 802.2.2....
Search Results "Clear Floor Space"
Commonly Searched Documents
-
Lines of Sight Over Standing Spectators: ADA Standard Section 802.2.2
-
Accessible - Changes in Level
Ramps where space limitations prohibit this may have slopes and rises as follows: a slope between 1:10 and 1:12 is allowed for a maximum rise of 6", and a slope between 1:8 and 1:10 is allowed...
-
Lines of Sight Over Seated Spectators: ADA Standard Section 802.2.1
Where spectators are expected to remain seated during events, spectators in wheelchair spaces shall be afforded lines of sight complying with 802.2.1....
-
Sec.36.304(f) Selling or serving space
(f) Selling or serving space....
- Guide for Home Remodeling for People with Disabilities and Special Needs: What You Need to Know
-
11B-802.2.2 Lines of sight over standing spectators
Where spectators are expected to stand during events, spectators in wheelchair spaces shall be afforded lines of sight complying with Section 11B-802.2.2....
-
Balco FMS-A Floor Mat with Extruded Vinyl Edge Section
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-802.2.1 Lines of sight over seated spectators
Where spectators are expected to remain seated during events, spectators in wheelchair spaces shall be afforded lines of sight complying with Section 11B-802.2.1....
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302....
-
Spa
Plants throughout to remove contaminants and increase oxygen levels Weights, treadmill, and wind trainer, and ceiling mounted TV in a beautiful space (not hidden in the basement...
-
11B-227.2 Check-out aisles
Exception: In existing buildings, where the selling space is under 5000 square feet (465 m2) no more than one check-out aisle complying with Section 11B-904.3 shall be required....
-
11B-302.3 Openings
Openings in floor or ground surfaces shall not allow passage of a sphere more than ½ inch (12.7 mm) diameter except as allowed in Sections 11B-407.4.3 _|Platform to Hoistway Clearance|_,...
-
11B-703.8.8 Line spacing
11B-703.8.8 Line spacing. Low resolution VMS characters shall comply with Section 11B-703.5.9....
-
11B-703.8.8 Line spacing
11B-703.8.8 Line spacing. Low resolution VMS characters shall comply with Section 11B-703.5.9....
-
1014.3.2 Slope
The slope of the floor surface shall not be steeper than 1:48 in any direction....
-
1014.3.2 Slope
The slope of the floor surface shall not be steeper than 1:48 in any direction....
-
304.1 General
Turning space shall comply with 304....
-
304.1 General
Turning space shall comply with 304....
-
304.1 General
Turning space shall comply with 304....
-
304.1 General
Turning space shall comply with 304....
-
General [5.1]/ Access Aisles [5.3]
The required clear width (36 inches minimum) is specified for the clearance between the edges of fixed tables or between table edges and walls....
-
304.3 Size
Turning space shall comply with 304.3.1 or 304.3.2....
-
304.1 General
Turning space shall comply with 304....
-
11B-304.1 General
Turning space shall comply with Section 11B-304....