The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches, and the transition from roadway or sidewalk...
Search Results "Barrier Wall"
Commonly Searched Documents
-
§ 38.23(b)(8) Platform entrance ramp
-
Minimum Required Attributes
transition plan consist of the following: 1) Identification of the official responsible for implementation of the transition plan (See 28 CFR 35.150(d)(3)(iv)); 2) An inventory of barriers...
- Handbook of Construction Tolerances by David Kent Ballast FAIA, CSI
-
ADA Compliance Motivators & Strategies
Then there was the organization who decided to hire a consultant to survey their facilities for barriers to people with disabilities and make recommendations for barrier removal....
-
Marilyn Golden - 2014 Champion of Change in Transportation
Requires the Registered User plan or above. Login!
-
Clear floor space
It appears that a minimum 6'-6" rear wall would be required if bench is parallel to a wall?...
- Cal-Royal 300 Series Hydraulic Door Closers
-
11B-405.2 Slope
range of users, provide ramps with the least possible running slope and, wherever possible, accompany ramps with stairs for use by those individuals for whom distance presents a greater barrier...
-
5.1 Tell the Doctor and the Staff
Often, the health care facility is unaware that any problems exist and simple statements will make them aware of barriers....
-
§ 38.125(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
-
§ 38.83(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8 measured on level ground, for a maximum rise of 3 inches, and the transition from the station platform...
-
§ 38.95(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
-
Re: 404.2.4.3 Recessed Doors and Gates
A barrier within 18" of the latch side of a push approach door will trigger the extra requirements....
-
11B-805.6 Hand washing fixtures, lavatories and sinks
inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with a built-in lavatory or at the front edge of a wall-mounted...
-
3. Lavatory knee clearance
the floor, a 27-inch-high clearance for knee space extending at least 8 inches from the front of the lavatory, and a 9-inch-high toe space extending not more than 6 inches from the back wall...
-
609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm)....
-
804.3.1 Clear Floor or Ground Space
conditions are met: (a) the cabinetry can be removed without removal or replacement of the kitchen work surface; (b) the finish floor extends under the cabinetry; and (c) the walls...
-
Alteration
renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement of the structural parts or elements, and changes or rearrangement in the plan configuration of walls...
-
1133A.3 Removable base cabinets
The finish floor beneath kitchen sinks and work surfaces shall be extended to the wall....
-
Single-User Toilet Rooms: No Side Transfer Space
Single-User Toilet Rooms: No Side Transfer Space On single plumbing walls, lavatories can overlap water closet clear floor space although this precludes side transfers....
-
609.3 Spacing
The space between the wall and the grab bar shall be 1 1/2 inches (38 mm)....
-
Knee Clearance: Clearance as Measured from Anterior-Most Point - Manual Wheelchair
Shaded areas depict the envelope of space required by the specified percentage of people if positioned with the forward-most point touching the wall....
-
11B-610.2 Bathtub seats
Permanent seats at the head end of the bathtub shall be 15 inches (381 mm) deep minimum and shall extend from the back wall to or beyond the outer edge of the bathtub....