Alterations and water closet clearances in single-user toilet rooms with in-swinging doors....
Search Results "Altered Elevator"
-
Alterations and water closet clearances in single-user toilet rooms with in-swinging doors. (Section-by-Section Analysis)
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
11B-411.2.1.6 Identification of floors served
In buildings with two or more elevator banks, each serving a different group of specific floors, hall call consoles located on floors with a building entry, including parking and transfer...
-
Audible Hall Signals
Comments from the elevator industry indicated that hall signals currently fall within this range. Response....
-
Reasonable Modification of Policies, Practices, and Procedures
state that public entities must modify policies, practices and procedures when necessary to assure a person with a disability an equal opportunity, unless to do so would fundamentally alter...
-
Are side flares required at curb ramps?
Side flares are essential in alterations when space for a top landing (36” deep min.) is not available; in this instance, side flares (1:12 max. slope) are necessary to accommodate wheelchair...
-
4.4.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Alterations to Qualified Historic Facilities [§202.5]
Alterations to Qualified Historic Facilities [§202.5] The standards contain specific provisions for qualified historic facilities which are defined as buildings or facilities that...
-
§ 36.401(d) Elevator exemption.
(d) Elevator exemption....
-
Play areas. (Section-by-Section Analysis)
to their elevated play components. ...
-
III-4.3600 Limitations and alternatives
A public accommodation is not required to provide any auxiliary aid or service that would fundamentally alter the nature of the goods or services offered or that would result in an undue...
-
21. Q: Is there a limit to the amount of money my agency must spend to alter an existing police facility?
Your agency is not required to undertake alterations that would impose undue financial and administrative burdens....
-
General: ADA Standard Section 210.1
Section 210.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for stairways.
-
11B-202 Existing buildings and facilities
SECTION 11B-202 Existing buildings and facilities 11B-202.4 Path of travel requirements in alterations, additions and structural repairs Exceptions: 8....
-
§ 35.151(b)(4)(i)(B)
(B) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of or access...
-
§ 35.151(b)(4)(i)(B)
(B) For the purposes of this section, alterations to windows, hardware, controls, electrical outlets, and signage shall not be deemed to be alterations that affect the usability of or access...
-
106.5.57 Safe Harbor
Elements of a path of travel at a subject building or facility that have been previously constructed or altered in accordance with the April 1, 1994 Texas Accessibility Standards (TAS) are...
-
Elevator Exemption (Section-By-Section Analysis and Response to Comments)
Elevator Exemption (Section-By-Section Analysis and Response to Comments) Section 36.401(d) implements the "elevator exemption'' for new construction in section 303(b) of the ADA....
-
§ 36.405(a)
(a) Alterations to buildings or facilities that are eligible for listing in the National Register of Historic Places under the National Historic Preservation Act (16 U.S.C. 470 et seq) or...
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.2.3.1 Floor designation
Floor designations complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances....
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated...
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.