Outdoor rinsing showers shall provide at least one hand-held shower spray unit with a hose 59 inches (1500 mm) long minimum....
Search Results "UNCRPD (United Nations Convention on the Rights of Persons with Disabilities)"
Commonly Searched Documents
-
1011.7 Outdoor Rinsing Showers
-
1011.7 Outdoor Rinsing Showers
Outdoor rinsing showers shall provide at least one hand-held shower spray unit with a hose 59 inches (1500 mm) long minimum....
-
‘‘Facility.’’
Facility’’ means all or any portion of buildings, structures, sites, complexes, equipment, rolling stock or other conveyances, roads, walks, passageways, parking lots, or other real or personal...
-
F233.3.3.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration, at least 5 percent of the residential dwelling units shall comply with 809.2 through 809.4 and shall be on an accessible route...
-
Requirement 4 -- Accessible Route Into and Through the Unit
[See subsections ...]
-
Scenario 7 – Reevaluations and FAPE
Salim is a student with a disability and he has a Section 504 plan. At the start of the spring semester, he received an out-of-school suspension for 12 consecutive school days....
-
1133A.2, Item 1
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in a wheelchair shall be provided at the range or cooktop....
-
1133A.2, Item 1
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a person in a wheelchair shall be provided at the range or cooktop....
-
36 CFR Part 1192 Americans with Disabilities Act (ADA) Accessibility Guidelines for Transportation Vehicles (2016 Non-Rail Vehicle Guidelines)
The revised guidelines ensure that such vehicles are readily accessible to, and usable by, individuals with disabilities. The U.S....
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1133A.2.1, Item 3
3. All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A).
-
1132A.4.1, Item 1
1. Thresholds with a change in height of not more than ¼ inch (6.35 mm) may be vertical.
-
1136A.1 Receptacle heights
1136A.1 Receptacle heights. Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall be located no more than 48 inches (1219...
-
1132A.8 Hand-activated door hardware
1132A.8 Hand-activated door hardware. Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
Research Projects
The Board sponsors and coordinates research for use in developing accessibility guidelines and providing technical assistance to the public. The Board’s research program is focused...
-
1132A.7 Type of lock or latch
1132A.7 Type of lock or latch. The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1133A.5 Lower shelving
1133A.5 Lower shelving. Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor.
-
Notifying the U.S. Access Board About Exemptions
Infrequently, an entire beach access route must be exempted from the technical requirements because extreme or numerous conditions for exemptions make it impractical to provide a...
-
4.34.2(14)
(14) If laundry facilities are provided, they shall comply with 4.34.7.
-
A4.34.6.7 OVENS
Countertop or wall-mounted ovens with side-opening doors are easier for people in wheelchairs to use. Clear spaces at least 30 in (760 mm) wide under counters at the side of ovens...
-
F245.2.5.1 Outdoor Constructed Features
Where provided, at least one of each type of outdoor constructed feature shall comply with 1011. Where more than one of the same type of outdoor constructed feature is provided, at...
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor. Latching and locking doors that are...
-
1132A.7 Type of lock or latch
The type of latch and lock required for all doors shall be in accordance with Section 1132A.8 and Chapter 10, Section 1008.
-
1133A.2.1, Item 3
3. All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A).