The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
Search Results "Seat Height"
Commonly Searched Documents
-
11B-1009.4.2 Height
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
Plan 3A: 12-Foot Wide Accessible Guest Room
Features include a bathtub with a seat, comparable vanity, open clothes closet, and door connecting to adjacent guest room....
-
Plan 1A: 13-Foot Wide Accessible Guest Room
Features include a standard bathtub with a seat, comparable vanity, clothes closet with swinging doors, and door connecting to adjacent guest room....
-
M101.2 Application (Section-by-Section Analysis)
The first is to exempt examination chairs which comply with M302 and can be reclined to facilitate diagnosis after the patient transfers onto the seat from complying with M301....
-
Protocol C Heights Obtained
For the maximum height transfers HERL's percentile heights were slightly higher for the 25th and 75th percentiles than the NDVWSC heights....
-
II. Recommendations of Diagnostic Imaging Equipment Manufacturers on Transfer Surface Low Height
two surfaces, in one direction or the other.” 1 The NPRM then goes on to discuss wheelchair seat heights, with the 5th percentile lowest seat height being 17.3 inches, according to the...
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
Check-Out Aisles and Sales and Service Counters
Where the counter is a single-height counter, this requirement applies across the entire depth of the counter top....
-
§ 38.125(d) Seating
(d) Seating—...
-
Adjustable height/gap protocol
Adjustable height/gap protocol: From the initial setup, a gap separating the device and platform was introduced with the plywood blocks of 3.5” (8.9cm) and then the height of platform was...
-
Adjustable height/gap protocol
Number of subjects that were able to attain a certain gap at a certain height under adjustable height/gap protocol Height\Gap 3.5" 7"...
-
4.34.5.4 BATHTUBS
If a bathtub is provided, then it shall have the following features:
-
Check Height and Location of the Pushbutton
Check Height and Location of the Pushbutton Confirm that pushbutton height and location conform to specifications and can be reached by a person in a wheelchair, from a hard surfaced level...
-
11B-226.3 Dining surfaces exceeding 34 inches in height
Where food or drink is served for consumption at a counter exceeding 34 inches (864 mm) in height, a portion of the main counter 60 inches (1525 mm) minimum in length shall be provided in...
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. EXCEPTION: Transfer surfaces for imaging equipment with bores shall be...
-
M301.2.3.2 Side Transfer Surface
Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum. EXCEPTION: Transfer surfaces for imaging equipment with bores shall be...
-
M301.2.4 Unobstructed Transfer
Each transfer surface shall provide two unobstructed sides for patient transfer. EXCEPTIONS: 1. Obstructions no more than 3 inches (75 mm) deep shall be permitted to extend beyond...
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M301.4.1 or M301.4.2. EXCEPTION: Where fixed overhead patient...
-
M301.2.4 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as...