The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
Search Results "Recessed Toilet Paper Dispenser"
-
11B-604.3.2 Overlap
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
AUTOMATIC TELLER MACHINE (ATM)
[DSA-AC] Any electronic information processing device which accepts or dispenses cash in connection with a credit, deposit, or convenience account....
-
Hall Call Buttons [4.10.3]
(Buttons can be flush, but not recessed)....
- AJW Architectural Products U7204 Series 16"W x 22"H Unidoor Medicine Cabinet - Recessed
- AJW Architectural Products U720 Series 16"W x 22"H Medicine Cabinet - Recessed
-
Standard Units
Recessing units in alcoves, wing walls, or other means of providing a detectable leading edge at or below 27 inches are acceptable....
-
11B-407.2.1 Call controls
[2010 ADAS] EXCEPTION: Existing elevators shall be permitted to have recessed call buttons....
-
11B-407.2.1 Call controls
[2010 ADAS] EXCEPTION: Existing elevators shall be permitted to have recessed call buttons....
-
11B-213.3.4 Lavatories
Where lavatories are provided, at least 10 percent but no fewer than one shall comply with Section 11B-606 and shall not be located in a toilet compartment....
-
11B-213.3.4 Lavatories
Where lavatories are provided, at least 10 percent but no fewer than one shall comply with Section 11B-606 and shall not be located in a toilet compartment....
-
Flush Controls: ADA Standard Section 604.6
Section 604.6 covers the current ADA Standards for water closets flush controls.
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
Clear Floor Space [4.19.3]
Recommendations:Consider locating towel dispensers within reach from the lavatory so that people can dry their hands before maneuvering wheelchairs....
-
11B-407.2.1 Call controls
[2010 ADA Standards] EXCEPTION: Existing elevators shall be permitted to have recessed call buttons....
-
Maneuvering Clearances at Doors [4.13.6]
Clearance to the wall plane next to the door (even when the door is in a recess) is essential....
-
Exhibit Design Relating to Low Vision and Blindness: Tactile Mapping for Cultural and Entertainment Venues
Tactile mapping for cultural and entertainment venues (White paper). Indiana University, Bloomington, IN....
- American Specialties Security Recessed Shelf 130
- Bobrick Recessed Sharp Disposal B-35016
- Bobrick Recessed Medicine Cabinet B-397
- Bobrick Recessed Medicine Cabinet B-398
-
Side Approach
Recommendation: Since a close approach is often necessary, this space is helpful even at recesses less than 15 inches deep....
- Salsbury Industries Recessed Mounted Cell Phone Storage Locker 5 Door High Unit