Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
Search Results "Parking Space Width"
-
11B-705.1.1.2 Dome spacing
-
11B-1008.4.2 Clear floor or ground space
Clear floor or ground space complying with Sections 11B-305.2 and 11B-305.3 shall be provided at play components. [2010 ADAS] Advisory 1008.4.2 Clear Floor or Ground Space. ...
-
§ 38.125(d)(2) Wheelchair or mobility aid spaces
(2) Wheelchair or mobility aid spaces. Spaces for persons who wish to remain in their wheelchairs or mobility aids shall have a minimum clear floor space 48 inches by 30 inches....
-
T602 Wheelchair Spaces
Wheelchair spaces must also be 30 inches minimum in width and 48 inches minimum in length. See T602.4....
-
1014.2.1.1 Clear Ground Space
A clear ground space shall be provided at the entrance to the camp shelter. ...
-
1014.2.1.1 Clear Ground Space
A clear ground space shall be provided at the entrance to the camp shelter....
-
§ 38.123(a)(5)
(5) Doorways on the end of the enclosure, opposite the water closet, shall have a minimum clear opening width of 32 inches....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-705.1.1.2 Dome spacing
11B-705.1.1.2 Dome spacing....
-
304.3.1 Circular Space
304.3.1 Circular Space. The turning space shall be a space of 60 inches (1525 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with 306....
-
11B-902.2.1 Overlap
The clear floor space at dining surfaces shall not overlap the accessible route....
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Bus Shelters: ADA Standard Section 810.3
Bus shelters shall provide a minimum clear floor or ground space complying with 305 entirely within the shelter....
-
M303.2.3 Wheelchair Spaces / Depth of Wheelchair Spaces for front or Rear Entry
M303.2.3 Wheelchair Spaces / Depth of Wheelchair Spaces for front or Rear Entry • Sub-Committee Recommendation: The Sub-committee and Full Committee have decided not to act on the proposed...
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
10.3.1(7)*
Accessible fare collection devices shall have a minimum clear opening width of 32 in; shall permit passage of a wheelchair; and, where provided, coin or card slots and controls necessary...
-
Knee and Toe Space [§305.4 and §306]
Knee and Toe Space [§305.4 and §306] Objects that provide space for toes or knees can overlap a portion of the clear floor space....
-
1007.3 Enclosed exit stairways
An enclosed exit stairway, to be considered part of an accessible means of egress, shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate...
-
Check-Out Aisles: ADA Standard Section 227.2
Section 227.2 covers scoping requirements in the current ADA Standards for check-out aisles.
-
§100.304(b) housing facility or community
(b) For purposes of this subpart, housing facility or community means any dwelling or group of dwelling units governed by a common set of rules, regulations or restrictions. A...
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....
-
11B-1008.3.1.3 Transfer space
A transfer space complying with Sections 11B-305.2 and 11B-305.3 shall be provided adjacent to the transfer platform....