Doorways at Landings [§405.7.5] Required door maneuvering clearances can overlap ramp landings (it is advisable to locate the swing of doors outside ramp landings for greater safety)....
Search Results "Curb Ramp Surface"
-
Doorways at Landings [§405.7.5]
-
11B-503.4 Floor and ground surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle pull-up space they serve. Changes in...
-
11B-503.4 Floor and ground surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle pull-up space they serve. Changes in...
-
11B-812.3 Floor or ground surfaces
Vehicle spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle space they serve. Changes in level, slopes...
-
11B-812.3 Floor or ground surfaces
Vehicle spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the vehicle space they serve. Changes in level, slopes...
-
1.1.4 Walk cross slope
at one end of the walking surface....
- Ytterberg Scientific Inc. FloorPro® Floor Flatness Measurement Device
-
1131A.2 Changes greater than ½ inch
Changes in level greater than ½ inch (12.7 mm) shall be made by means of a sloped surface not greater than 1 unit vertical in 20 units horizontal (5-percent slope), or a ramp, elevator or...
-
1132A.4, Item 3
Secondary exterior doors onto decks, patios, or balcony surfaces constructed of impervious materials (e.g., concrete, brick, flagstone) may have a maximum change in height from the interior...
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
405.7.1 Slope
Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
405.7.1 Slope
Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
405.7.1 Slope
405.7.1 Slope. Landings shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.
-
4.8.5(7)
(7) Handrails shall not rotate within their fittings.
-
4.8.5(3)
(3) The clear space between the handrail and the wall shall be 1 - 1/2 in (38 mm).
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
11B-405.7.1 Slope
Landings shall comply with Section 11B-302. Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted.
-
11B-405.10 Wet conditions
Landings subject to wet conditions shall be designed to prevent the accumulation of water.
-
Clear Deck Space: ADA Standard Section 1009.2.3
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (915 mm) wide minimum and shall extend forward...
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (914 mm) wide minimum and shall extend forward...
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat. The space shall be 36 inches (914 mm) wide minimum and shall extend forward...
-
1009.8 Two-way communication
Two-way communication systems are not required on floors provided with ramps conforming to the provisions of Section 1012....