[2010 ADA Standards] 805.1 General....
Search Results "Referenced Standard"
-
11B-805.1 General
-
11B-407.4.10 Support rail
. ◼ ETA Editor's Note There is no requirement for support rails inside elevator cars in 2010 ADA Standards....
-
11B-407.2.2.2 Visible signals
[2010 ADA Standards] 2. Existing elevators shall not be required to comply with 407.2.2.2....
-
11B-703.5 Visual characters
[2010 ADA Standards] EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to comply with 703.5.2 through...
-
11B-215.3 Employee work areas
[2010 ADA Standards] 215.3 Employee Work Areas....
-
11B-703.5 Visual characters
[2010 ADA Standards] EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to comply with 703.5.2 through...
-
f-i
[ADA Standards § 4.8.2] Yes No Note: For existing ramps, the slope may be 1:10 for a 6-inch rise and 1:8 for a 3-inch rise in special circumstances (see ADA Standards § 4.1.6...
-
§100.60(b)(4)
(4) Using different qualification criteria or applications, or sale or rental standards or procedures, such as income standards, application requirements, application fees, credit analysis...
-
3.3.3 Clear Floor Width
The BS8300 standard’s developers may have added 100 mm to provide additional maneuvering room at clear floor areas....
-
"Housing at a Place of Education" definition
Place of Education,’’ and has revised Sec. 36.406(e) to reflect the accessible features that now will be required in addition to the requirements set forth under the transient lodging standards...
-
210 and 504 Stairways
210 and 504 Stairways The 1991 Standards require stairs to be accessible only when they provide access to floor levels not otherwise connected by an accessible route (e.g., where the...
-
L. Accessible Guest Rooms
Accessible Guest Rooms (1) Defendants will have 12 designated accessible rooms/ suites that comply with the 2010 Standards dispersed among the various classes of accommodations as follows...
-
3.3.6 Knee Clearance Height, minimum
The U.S. standard for knee clearance height is 685 mm (27 in.). The U.K....
-
PURPOSE AND LEGAL AUTHORITY
We are proposing to update our existing Electronic and Information Technology Accessibility Standards under section 508 of the Rehabilitation Act of 1973, (“508 Standards”), as well as our...
-
Subpart F-Certification of State Laws or Local Building Codes (Section-by-Section Analysis)
in the past to meet or exceed the 1991 Standards. ...
-
Section 1193.51 Compatibility [1193.41 in the NPRM] (Section-by-Section Analysis)
electronic text format on a cross-industry standard port....
-
502.3.3 Values (Section-by-Section Analysis)
An express requirement for values to be set programmatically would be new to the 508 Standards....
-
203 General Exceptions
The 1991 Standards, at section 4.1.1, contain an exception that exempts “non-occupiable” spaces that have limited means of access, such as ladders or very narrow passageways, and that are...
-
Toilet Rooms South (Briefing Theater)
See Standards § 4.13.11(2)(b). kk. The men's and women's toilet room stall door hardware requires tight grasping and twisting of the wrist. See Standards § 4.13.9. ll....
-
Table 1
Proposed Guidelines Contain Same Requirements as in DOJ 2010 Standards Table 1 analyzes requirements in the proposed guidelines that are the same as requirements in the DOJ 2010 Standards...
-
Accessible Surfaces Located In The Use Zone
Ground surfaces must be inspected and maintained regularly and frequently to ensure continued compliance with the ASTM F 1951-99 standard....
-
15(e)
subparagraph 15(a), HWI shall ensure that each Post-1993 Owned Hotel and Post-1993 Joint Venture Hotel has the required number of rooms for guests with hearing impairments, as set forth in ADA Standards...
-
12112(b)(6)
(6) using qualification standards, employment tests or other selection criteria that screen out or tend to screen out an individual with a disability or a class of individuals with disabilities...
-
Handrails Along Walkways
The 1991 Standards do not contain any technical requirement for handrails provided along walkways that are not ramps....