Clear floor space at kitchens shall comply with the following: A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows a parallel approach by a...
Search Results "Mobile Health Screening Unit"
-
1133A.2 Clear floor space
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following: Doors shall not be less than 6 feet 8 inches (2032 mm) in height. Swinging doors shall provide a net clear opening width of not less...
-
Section 35.151(k) Detention and correctional facilities (Section-by-Section Analysis)
the Department has determined that many detention and correctional facilities do not have enough accessible cells, toilets, and shower facilities to meet the needs of their inmates with mobility...
-
4.8.1 General
Outdoor rinsing showers shall provide a hand-held shower spray unit complying with ABAAS section 608.6....
-
Section 36.406(d) Social Service Center Establishments (Section-by-Section Analysis)
First, for the first time, residential dwelling units are explicitly covered in the 2004 ADAAG in section 233....
- Section 508 Awareness Video
-
11B-608.5.2 Standard roll-in type shower compartments
In standard roll-in type shower compartments, the controls, faucets, and the shower spray unit shall be located on the back wall of the compartment adjacent to the seat 16 inches (406 mm...
- Sensible Innovations AWARE App
-
24.1 Q. What types of grab bars should the reinforcement be designed to accommodate and what types may be used if the builder elects to install grab bars in some units at the time of construction?
A. The Guidelines do not prescribe the type of product for grab bars, or the structural strength for grab bars. The Guidelines only state that the necessary reinforcement must be...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
(5) Reinforced walls for grab bars
guidelines has been to subject powder rooms to the reinforced wall requirement when the powder room is the only toilet facility on the accessible floor of a covered multistory dwelling unit...
-
11B-213.2 Toilet rooms and bathing rooms
Where multiple single user portable toilet or bathing units are clustered at a single location, 5 percent, but no fewer than one, of the toilet units and bathing units at each cluster shall...
-
11B-233.1 General
For example: Section 206.5.4 requires all doors and doorways providing user passage in residential dwelling units providing mobility features to comply with Section 404; Section 206.7.6...
-
4.3.2(3)
(3) At least one accessible route shall connect accessible building or facility entrances with all accessible spaces and elements and with all accessible dwelling units within the building...
-
Radiologic Equipment
Many radiologic technologies also require the patient to keep still, which may be very difficult for some individuals with a mobility disability, including those with spasticity, tremor,...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
608.5.2 Standard Roll-In Type Shower Compartments
In standard roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the shower floor...
-
11B-608.5.2 Standard roll-in type shower compartments
Operable parts of the shower spray unit, including the handle, shall be installed on the back wall adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from...
-
11B-608.5.2 Standard roll-in type shower compartments
Operable parts of the shower spray unit, including the handle, shall be installed on the back wall adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from...
-
Section 5 Guidelines
entrance on an accessible route; (2) accessible and usable public common use areas; (3) doors usable by a person in a wheelchair, (4) accessible route into and through the covered dwelling unit...
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
11B-809.8.2 Door opening force
The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
11B-809.8.2 Door opening force
Doors shall comply with Section 11B-404.2.9. Exception: The opening force for primary entry exterior doors and secondary exterior doors shall be 8.5 pounds (38 N) maximum.
-
Alterations—28 CFR 35.151
In certain situations, application of the 2010 Standards may result in fewer units containing accessibility features....
