305.7.2 Parallel Approach. Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm). Figure 305.7.2 Maneuvering Clearance in an Alcove,...
Search Results "Electric Vehicle Charging Space"
Commonly Searched Documents
-
305.7.2 Parallel Approach
-
4.2.2 Width for Wheelchair Passing
The minimum width for two wheelchairs to pass is 60 in (1525 mm) (see Fig. 2).
-
4.2.2 WIDTH FOR WHEELCHAIR PASSING
The minimum width for two wheelchairs to pass is 60 in (1525 mm) (see Fig. 2).
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm)wide minimum where the depth exceeds 24 inches (610 mm).
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).
-
11B-308.2.2 Obstructed high reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
11B-802 Wheelchair spaces, companion seats, and designated aisle seats and semi-ambulant seats
[2010 ADAS] 802 Wheelchair Spaces, Companion Seats, and Designated Aisle Seats...
-
Clear floor space beside or between beds must be 36" wide
Remember that because the clear floor space required by 806.2.3 will be deeper than 24" to end up beside or between the beds where it will be usable, it will be in an alcove that is at least...
-
R309.5.1 Location
At accessible parallel parking spaces, parking meters shall be located at the head or foot of the parking space. Advisory R309.5.1 Location....
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
1009.4.3 Wall Depth and Length
The length of the transfer wall shall be 60 inches (1525 mm) minimum and shall be centered on the clear deck space....
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
-
11B-1009.4.3 Wall depth and length
The length of the transfer wall shall be 60 inches (1524 mm) minimum and shall be centered on the clear deck space....
-
§ 38.107(a)(4)
(4) Faucets and flush controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate controls shall...
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
Single-User Toilet Rooms: No Side Transfer Space