Transfer devices for use with amusement rides should permit individuals to make independent transfers to and from their wheelchairs or mobility devices....
Search Results "Permit"
-
11B-1002.6 Transfer devices for use with amusement rides
-
11B-609.3 Spacing
Exceptions: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1½ inches (38 mm) minimum....
-
11B-206.3 Location
An accessible route shall not pass through kitchens, storage rooms, restrooms, closets or other spaces used for similar purposes, except as permitted by Chapter 10. U.S....
-
11B-206.4 Entrances
Where exceptions for alterations to qualified historic buildings or facilities are permitted by 202.5, no more than one public entrance shall be required to comply with 206.4....
-
11B-206.3 Location
An accessible route shall not pass through kitchens, storage rooms, restrooms, closets or other spaces used for similar purposes, except as permitted by Chapter 10. U.S....
-
11B-809.10.6.1 Size
A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the...
-
1010.2.12.1 Delayed egress locking system
Exception: In facilities housing Alzheimer's or dementia clients, a delay of not more than 30 seconds is permitted on a delayed egress door. … 6....
-
11B-609.3 Spacing
Exceptions: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1½ inches (38 mm) minimum....
-
11B-302.1 General
A slip-resistant surface provides sufficient frictional counterforce to the forces exerted in walking to permit safe ambulation. ◼ Advisory 11B-302.1 General....
-
11B-1002.6 Transfer devices for use with amusement rides
Transfer devices for use with amusement rides should permit individuals to make independent transfers to and from their wheelchairs or mobility devices....
-
11B-206.2.1 Site arrival points
Where exceptions for alterations to qualified historic buildings or facilities are permitted by 202.5, no more than one accessible route from a site arrival point to an accessible entrance...
-
502.3.3 Values (Section-by-Section Analysis)
., 508 Standards § 1194.21(d)) is to permit values to be set programmatically....
-
410.6 Doors and Gates
EXCEPTION: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
11B-410.6 Doors and gates
Exception: Platform lifts serving two landings maximum and having doors or gates on opposite sides shall be permitted to have self-closing manual doors or gates....
-
Elevator Doors
In the draft of the final guidelines, the Board had included a reference to vertical sliding doors permitted by the elevator safety code (ASME A17.1) in response to this comment....
-
11B-211.3 More than minimum number
Exception: Where 50 percent of the drinking fountains yields a fraction, 50 percent shall be permitted to be rounded up or down provided that the total number of drinking fountains complying...
-
What is a "disability-related inquiry"?
Questions that are not likely to elicit information about a disability are always permitted, and they include asking employees about their general well-being; whether they can perform job...
-
604.4 Seats
In residential dwelling units, the height of water closets shall be permitted to be 15 inches (380 mm) minimum and 19 inches (485 mm) maximum above the finish floor measured to the top of...
-
Overlapping Clear Floor Space
The Board has clarified that accessible lavatories are permitted to overlap clear floor space "opposite the shower compartment side where shower controls are positioned or where a seat is...
-
11B-405.9.2 Curb or barrier
EDGE PROTECTION ETA Editor's Note 2013 CBC requires either a curb or a barrier for edge protection at ramps, and does not recognize the extended floor or ground surface also permitted...
-
New Elevators and Existing Elevators
Provisions specific to "existing" elevators in section 407 address certain allowances permitted in the alteration of standard elevators....
-
904.4 Sales and Service Counters
a counter complying with 904.4 would result in a reduction of the number of existing counters at work stations or a reduction of the number of existing mail boxes, the counter shall be permitted...
-
1007.6 Areas of refuge
The maximum travel distance from any accessible space to an area of refuge shall not exceed the travel distance permitted for the occupancy in accordance with Section 1015.1....
-
Maximum Slope at Ground Level
This is permitted since the handrails may become a safety hazard in the "use zone."...