The slope of the turning space in all directions shall be 1:48 maximum....
Search Results "Maximum Dimension"
Commonly Searched Documents
-
11B-406.3.2 Turning space
- AquaTrek2 ADA Step System
- Brady Worldwide Van Accessible Parking Sign 103750
- Omnia Industries Inc. Interior Modern Lever Latchset - Solid Brass No.225
- Omnia Industries Inc. Interior Modern Lever Latchset with Modern Round Rose - Solid Brass No.930MD
-
19 Inch Low Height
The highest and lowest points of the transfer surface on such equipment would have to be within the specified dimensions.”8 The Access Board proposed that the measurement should be taken...
-
1003 Recreational Boating Facilities
Requirements for accessible routes and ramps are applied to gangways, but exceptions to criteria for maximum rise and slope, handrail extensions, and level landings are provided....
-
M303.3.3.1 Running Slope
EXCEPTION: A running slope not steeper than 1:8 shall be permitted for ramp runs with a maximum height of 2 ½ inches (64 mm)....
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. Figure 810.10 (Exception) Track Crossings...
-
T603.4 Movement
Wheelchair securement systems shall limit the movement of an occupied wheelchair to 2 inches (51 mm) maximum in any direction when secured in accordance with the manufacturer’s instructions...
-
4.6.3 Eyepiece
eyepiece for the telescope or periscope that is usable from a seated position for viewing each point of interest shall be positioned 43 inches (1090 mm) minimum and 51 inches (1295 mm) maximum...
-
11B-602.7 Drinking fountains for standing persons
Spout outlets of drinking fountains for standing persons shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground....
- Pilot Rock APTX Snow Load/Extreme Load Full Size Pedestal Utility Table
-
1003.3.1 Boat Slip Clearance
Each 10 feet (3050 mm) maximum of linear pier edge serving boat slips shall contain at least one continuous clear opening 60 inches (1525 mm) wide minimum. EXCEPTIONS: 1....
-
Section 1.0 Background
It is likely that the current U.S. standards do not reflect the actual dimensions and abilities of contemporary WhMD users....
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor. Exceptions: 1. ...
-
M301.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches maximum....
-
6. Classroom Acoustics
ANSI), the “ANSI/ASA S12.60-2010 American National Standard Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools (Parts 1 and 2)” sets specific criteria for maximum...
-
Sloped Entries
Sloped Entries Sloped entries must comply with ADAAG accessible route provisions (36 inch minimum width, maximum 1:12 or 8.33% slope), except that the surface does not need to be slip...
-
6. Classroom Acoustics
ANSI), the “ANSI/ASA S12.60-2010 American National Standard Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools (Parts 1 and 2)” sets specific criteria for maximum...
-
505.4 Height
Top of gripping surfaces of handrails shall be 34 inches (865 mm) minimum and 38 inches (965 mm) maximum vertically above walking surfaces, stair nosings, and ramp surfaces....
-
604.8.1.2 Doors
Where located in the front partition, the door opening shall be 4 inches (100 mm) maximum from the side wall or partition farthest from the water closet....