Gangway Slope and Rise Exceptions Gangways must be designed to provide for a maximum 1:12 (8.33%) slope but are not required to be longer than 30 feet in length....
Search Results "Maximum Dimension"
Commonly Searched Documents
-
Gangway Slope and Rise Exceptions
-
Accessible Routes on the Playing Surface
When the accessible route is provided on the course, a 1-inch high maximum curb is permitted for an opening of 32 inches minimum where the accessible route extends outside the hole....
-
5.1 Transfer Surface Height Recommendations
The height of the transfer surface during patient transfer shall be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer surface....
-
11B-608.5.2 Standard roll-in type shower compartments
compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum...
-
11B-608.5.2 Standard roll-in type shower compartments
compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum...
-
11B-809.10.7.3 Reinforcement for grab bars
Where reinforcement is installed at the back, it shall be installed between 30 inches (762 mm) maximum and 38 inches (965 mm) minimum above the finish floor....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls. [2010 ADAS] 608.3.2 Standard Roll-In Type Shower Compartments. ...
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the wheelchair...
-
M305.3.2 Height (Section-by-Section Analysis)
For horizontal supports, the MDE NPRM proposed a gripping surface height of 34 inches minimum and 38 inches maximum above the standing surface....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
Submerged Depth
Submerged Depth Sloped entries must extend to a depth between 24 inches minimum and 30 inches maximum below the stationary water level....
-
407.2.2.3 Audible Signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
407.2.2.3 Audible Signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
Running Slope [1016.7.1]
Table 3—Maximum Running Slope and Segment Length Running Slope of Segment of Outdoor Recreation Access Route Maximum Length of Segment Steeper Than But Not...
-
11B-411.2.1.2.3 Accessibility function button
Each dot shall have a base diameter of 0.059 inch (1.5 mm) minimum and 0.063 inch (1.6 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
407.2.2.3 Audible Signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
Rise
The maximum length of a run is determined by the rise (30 inches maximum) and the slope: Max. Rise Slope Max. Length Max. Rise Slope Max....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls. [2010 ADAS] 608.3.2 Standard Roll-In Type Shower Compartments....
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor....
-
Self Contained, Closed Products - Side Reach Range
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
505.7.1 Circular Cross Section
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1¼ inches (32 mm) minimum and 2 inches (51 mm) maximum....