The height of the transfer surface during patient transfer shall be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer surface....
Search Results "Expected Maximum Flight Duration"
Commonly Searched Documents
-
5.1 Transfer Surface Height Recommendations
-
11B-608.5.2 Standard roll-in type shower compartments
compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum...
-
407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis)
The dimensions necessary to accommodate the full knee and toe space under ICT would be 27 inches high minimum, 25 inches deep maximum, and 30 inches wide minimum....
-
Cross Section of Gripping Surfaces
disabilities to firmly grasp the grab bars and support themselves during transfers: • Grab bars with circular cross sections must have an outside diameter of 1¼ inches minimum and 2 inches maximum...
-
11B-608.5.2 Standard roll-in type shower compartments
compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum...
-
11B-809.10.7.3 Reinforcement for grab bars
Where reinforcement is installed at the back, it shall be installed between 30 inches (762 mm) maximum and 38 inches (965 mm) minimum above the finish floor....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls. [2010 ADAS] 608.3.2 Standard Roll-In Type Shower Compartments. ...
-
611 Washing Machines and Clothes Dryers
The proposed rule required the door of top loading machines and the door opening of front loading machines to be 34 inches maximum above the floor (611.4)....
-
M303.2.4.2.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum measured from the toe end of the wheelchair...
-
M305.3.2 Height (Section-by-Section Analysis)
For horizontal supports, the MDE NPRM proposed a gripping surface height of 34 inches minimum and 38 inches maximum above the standing surface....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
Submerged Depth
Submerged Depth Sloped entries must extend to a depth between 24 inches minimum and 30 inches maximum below the stationary water level....
-
407.2.2.3 Audible Signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
407.2.2.3 Audible Signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
Running Slope [1016.7.1]
Table 3—Maximum Running Slope and Segment Length Running Slope of Segment of Outdoor Recreation Access Route Maximum Length of Segment Steeper Than But Not...
-
11B-411.2.1.2.3 Accessibility function button
Each dot shall have a base diameter of 0.059 inch (1.5 mm) minimum and 0.063 inch (1.6 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
407.2.2.3 Audible Signals
Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a frequency of 300 Hz minimum and 3000 Hz maximum....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
Rise
The maximum length of a run is determined by the rise (30 inches maximum) and the slope: Max. Rise Slope Max. Length Max. Rise Slope Max....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls. [2010 ADAS] 608.3.2 Standard Roll-In Type Shower Compartments....
-
11B-812.10.4 Location
circulation path is not provided adjacent to the head end of the vehicle space or access aisle, the EV charger may be located within the projected width of the access aisle 36 inches (914 mm) maximum...
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor....