Section 405.5 covers the current ADA Standards for the clear width requirements of ramps.
Search Results "Direction of Travel"
-
Clear Width: ADA Standard Section 405.5
-
Floor Surfaces: ADA Standard Section 407.4.2
Section 407.4.2 covers the current ADA Standards for the floor surfaces of elevator cars.
-
Operable Parts: ADA Standard Section 602.3
Section 602.3 covers the current ADA Standards for the operable parts of drinking fountains.
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
-
Size: ADA Standard Section 604.8.2.1
Section 604.8.2.1 covers the current ADA Standards for the size of ambulatory accessible compartments.
-
Height: ADA Standard Section 606.3
Section 606.3 covers the current ADA Standards for the height of lavatories and sinks.
-
Location: ADA Standard Section 604.2
Section 604.2 covers the current ADA Standards for the mounting location of water closets.
- American Standard Serin 1 - Handle Monoblock Bidet Faucet
- Sargent Wall and Frame Switch Interface for Door Operators
- SuperDeck Nature Trail
-
11B-703.4.2 Location
Where provided, signs identifying exits shall be located at the exit door when approached in the direction of egress travel. [2010 ADAS] 703.4.2 Location. ...
-
Clear Tread Width and Passing Spaces for Outdoor Recreation Access Routes
Clear tread width means the width of the traveled surface on the ground and also above the ground between obstacles (figure 40)....
-
11B-703.4.2 Location
Where provided, signs identifying exits shall be located at the exit door when approached in the direction of egress travel. [2010 ADAS] 703.4.2 Location....
-
11B-703.4.2 Location
Where provided, signs identifying exits shall be located at the exit door when approached in the direction of egress travel. [2010 ADA Standards] 703.4.2 Location....
-
May an employer ask disability-related questions or require a medical examination when an employee who has been on leave for a medical condition wants to return to work?
Yes, if an employer has a reasonable belief that an employee's present ability to perform essential functions will be impaired by a medical condition or that he or she will pose a direct...
-
USE OF THE WAY
Once notified, people who are deaf or hard of hearing can read and follow standard exit and directional signs and use any standard means of egress from the building....
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
Floor [1014.3]
When the floor surface is constructed of asphalt, concrete, or boards, the slope of the floor surface must be no steeper than 1:48 (2 percent) in any direction, regardless of the type of...
-
R304.2.1 Turning Space
The 1.5 m (5.0 ft) dimension shall be provided in the direction of the ramp run....
-
R304.3.1 Turning Space
The 1.5 m (5.0 ft) dimension shall be provided in the direction of the pedestrian street crossing....
-
907.2.6.2.2 Manual fire alarm boxes
Manual fire alarm boxes are not required to be located in accordance with Section 907.3 where the fire alarm boxes are provided at staff-attended locations having direct supervision over...
-
Minimal protection.
minimal protection" from its regulation, the Department continues to believe that the language serves the important function of excluding from coverage so-called "attack dogs" that pose a direct...
-
1607A.8.2 Grab bars, shower seats and dressing room bench seats
Grab bars, shower seats and dressing room bench seat systems shall be designed to resist a single concentrated load of 250 pounds (1.11 kN) applied in any direction at any point on the grab...
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....