For the purposes of this part, an alteration is a change to a place of public accommodation or a commercial facility that affects or could affect the usability of the building or facility...
Search Results "Building Official"
Commonly Searched Documents
-
§ 36.402(b) Alteration.
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation, and carbon monoxide detection...
-
206.5.2 Rooms and Spaces
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
-
Sec.36.402(b) Alteration
For the purposes of this part, an alteration is a change to a place of public accommodation or a commercial facility that affects or could affect the usability of the building or facility...
-
Facility
All or any portion of buildings, structures, site improvements, complexes, equipment, roads, walks, passageways, parking lots, or other real or personal property located on a site....
-
Handrails [4.9.4]
A center rail is not specified for wide stairways by ADAAG but may be required by local building or life safety codes....
-
11B-206.2.2 Within a site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements and accessible spaces that are on the same site."...
-
1.4 Accessible Route Requirements
1.4 Accessible Route Requirements: For additions, the new construction provisions require an accessible route from the area of the addition to other accessible areas of the building, site...
-
Public entrances (Section-By-Section Analysis and Response to Comments)
- Generally, at least 50% of public entrances to new buildings must be accessible, rather than all entrances, as would often have resulted from the proposed approach....
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
-
1.9.1.1.3
1.9.1.1.3 All publicly funded buildings used for congregate residences or for one- or two-family dwelling unit purposes shall conform to the provisions applicable to living accommodations...
- HEWI Stainless Steel Pull Handles
-
Accessible Jury Boxes, Attorney Areas, and Witness Stands
Section 206.2.4 of the 2010 Standards requires, in new construction and alterations, at least one accessible route to connect accessible building or facility entrances with all accessible...
-
Shopping Center or Shopping Mall
(1) A building housing five or more sales or rental establishments; or (2) A series of buildings on a common site, either under common ownership or common control or developed either...
-
907.5.2.3.5 Groups R-2.1, R-3.1 and R-4
ETA Editor's Note Remainder of California Building Code Chapter 9, not adopted by Division of the State Architect - Access Compliance (DSA-AC), omitted. ...
-
16. If, as a reasonable accommodation, an employer restructures an employee's job to eliminate some marginal functions, may the employer require the employee to take on other marginal functions that s/he can perform?
Example: A cleaning crew works in an office building. One member of the crew wears a prosthetic leg which enables him to walk very well, but climbing steps is painful and difficult....
-
4.1.6(1)(j) EXCEPTION
Any elements or features of the building or facility that are being altered and can be made accessible shall be made accessible within the scope of the alteration....
-
106.5.60 Shopping Center or Shopping Mall
A building housing five or more sales or rental establishments; or a series of buildings on a common site, either under common ownership or common control or developed either as one project...
-
Area of Refuge Identification [IBC §1007.6.5 (2003), §1003.2.13.5.5 (2000)]
In addition, areas of refuge are not required in open parking garages, apartment buildings, detention and correctional facilities, or open exit stairways between floors in buildings with...
-
11B-206.6 Elevators
Exceptions: In a building or facility permitted to use the exceptions to Section 11B-206.2.3 or permitted by Section 11B-206.7 to use a platform lift, elevators complying with Section...
-
When is accessibility required for a live work conversion project?
Background The building is a 2-story concrete structure with 37,690 sf on the first floor and 22,334 sf on the second floor The building’s freight elevator has been vacated/removed...
-
Elevator requirement to new dining area on the mezzanine of an existing facility
Let's assume that this building meets all requirements of 206.2.3 Exception 1 so no elevator is required in the building. ...
-
Intent
Its primary focus is 2019 California Building Code (2019 CBC) Chapter 11B - Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, but it includes...
-
11B-202.3.1 Prohibited reduction in access
An alteration that decreases or has the effect of decreasing the accessibility of a building or facility below the requirements for new construction at the time of the alteration is prohibited...