., an accessible toilet; adequate catheters; or a shower chair)....
Search Results "Shower Slope"
Commonly Searched Documents
-
Program requirements. (Section-by-Section Analysis)
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
R408.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
Built-up Curb Ramps [4.7.6]
(The surface of access aisles cannot slope more than 2% in any direction)....
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
1) Where the Standard specifically refers to 303
such as 403.4 changes in level for walking surfaces: Here it is clear that changes in level that comply with either the ¼" maximum vertical rise, the ½" maximum beveled rise with a slope...
-
4.7.5 SIDES OF CURB RAMPS
If a curb ramp is located where pedestrians must walk across the ramp, or where it is not protected by handrails or guardrails, then it shall have flared sides; the maximum slope of the...
-
Post-Mounted Objects [§307.3]
The 12” limit also applies to the clearance between multiple posts (excluding the sloping portions of handrails)....
-
Thresholds [§404.2.5]
A maximum height of 3/4” is permitted for existing or altered thresholds if they have a beveled edge on each side with a slope not steeper than 1:2....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-404.2.5 Thresholds
[2010 ADAS] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply...
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
- Self Reliance, Inc. - Tampa, FL
- Pressalit Care PLUS - Bathroom Product Range Overview
-
Trail Study Sites
Layout of the path across the beach was sloped so that the edge of the path would not hold water....
-
504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
Clear Deck Space
Clear Deck Space The base of the transfer platform must have a clear deck space adjacent to it that is 60 by 60 inches minimum, with a slope not steeper than 1:48 so a person using a...
-
Accessible Routes
The accessible route must comply with ADAAG provisions for location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level,...
-
504.5 Nosings
Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical....
-
§35.150(d)(2)
(2) If a public entity has responsibility or authority over streets, roads, or walkways, its transition plan shall include a schedule for providing curb ramps or other sloped areas where...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...