1.2.7 When local variations (flatness) for cross slope of ramps are measured according to 1.1.14 at least 80% (rounded to the nearest whole number) should not exceed a 2% slope. The...
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
1.2.7
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
surface on the opposite side of the transfer....
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25 inches....
-
4.35.4 Bench
The bench shall be mounted 17 in to 19 in (430 mm to 485 mm) above the finish floor....
- AccessRec GrassProtecta Slip Resistant Grass Reinforcement Mesh
- Diversified Woodcrafts ADA Instructor's Desk 1214K-L-ADA
-
5.2.1.4 Transfer Surface Size for Imaging Equipment
5.2.1.4 Transfer Surface Size for Imaging Equipment. The transfer surface should be 28 inches wide minimum and 21 inches deep minimum....
-
1133A.4, Item 2
A minimum linear length of 30 inches (762 mm) of countertop shall be provided for a work surface....
-
1133A.4, Item 2
A minimum linear length of 30 inches (762 mm) of countertop shall be provided for a work surface....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
- Precision Safe Sidewalks LLC Sidewalk Trip Hazard Repair Service
- Varidesk Pro Desk Series: the Pro Desk 60
- Pro Desk Series Description - VARIDESK
- Humanscale's Float Height-Adjustable Table
- Steelcase Ology Series height-adjustable tables
-
10.3.1(9)
(9) In stations covered by this section, rail-to-platform height in new stations shall be coordinated with the floor height of new vehicles so that the vertical difference, measured when...
-
Forward Approach
For wheelchair access, the proposed rule required a forward approach at cantilevered units but allowed a parallel approach at other types of units, such as those that are floor mounted....
-
How to Use this Checklist
Obtain Floor Plan or Make Sketch A floor plan helps the surveyors to get organized and to know how many elements there are, such as entrances and toilet rooms. ...
-
What kinds of treatments constitute maintenance rather than an alteration?
Treatments that serve solely to seal and protect the road surface, improve friction, and control splash and spray are considered to be maintenance because they do not significantly affect...
-
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302 The Committee recommends adjustable height in small, virtually continuous increments....
- Populas Vox Corner Office Workstation
-
M302.2.5 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as they...
-
4.2.4.1 SIZE AND APPROACH
The minimum clear floor or ground space required to accommodate a single, stationary wheelchair occupant is 30 in by 48 in (760 mm by 1220 mm) (see Fig. 4(a))....