The rear wall grab bar shall be 36 inches (915 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
Search Results "Wing Wall"
Commonly Searched Documents
-
604.5.2 Rear Wall
- Nana Wall Systems, Inc. Sliding Glass Walls HSW60 Video
-
1011.5.3 Raised Edges or Walls
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....
-
1011.5.3 Raised Edges or Walls
Where fire rings, grills, or fireplaces are constructed with raised edges or walls, the depth of the raised edge or wall shall be 10 inches (255 mm) maximum....
-
11B-604.5.1 Side wall
11B-604.5.1 Side wall....
-
SECTION 704 EXTERIOR WALLS
SECTION 704 EXTERIOR WALLS...
-
11B-604.5.1 Side wall
The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with...
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. ...
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach....
-
711.3 Fire-resistance-rated walls
Penetrations into or through fire walls, fire barriers, smoke barrier walls, and fire partitions shall comply with this section....
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-604.5.2 Rear wall
11B-604.5.2 Rear wall....
-
(5) Reinforced walls for grab bars
The final Guidelines for bathroom wall reinforcement remains essentially unchanged from the Option One guidelines....
-
11B-604.5.2 Rear wall
The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) minimum on...
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
Requirement 6. Reinforced walls for grab bars.
building entrance on an accessible route shall be designed and constructed in such a manner that all premises within covered multifamily dwelling units contain reinforcements in bathroom walls...
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach. ...
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach....
-
Fur out the wall
The water closet shall be positioned with a wall or partition to the rear and to one side....
- Rakks® Wall Mounted Standards with Rakks® Brackets
-
11B-606.6 Adjacent side wall or partition
11B-606.6 Adjacent side wall or partition....
-
1134A.7, Item 1
FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET Exception: The 48-inch (1219 mm) minimum clear width may be reduced to 36 inches (914 mm) for lavatories, cabinets, wing walls, or...
-
11B-606.6 Adjacent side wall or partition
Lavatories, when located adjacent to a side wall or partition, shall be a minimum of 18 inches (457 mm) to the centerline of the fixture....
-
11B-606.6 Adjacent side wall or partition