1.9.1.2.1 Any building, structure, facility, complex or improved area, or portions thereof, which are used by the general public. Advisory 1.9.1.2.1....
Search Results "Structural Strength"
Commonly Searched Documents
-
1.9.1.2.1
-
1.9.1.2.1
1.9.1.2.1 Any building, structure, facility, complex or improved area, or portions thereof, which are used by the general public. Advisory 1.9.1.2.1....
-
Gaps: ADA Standard Section 1002.4.3
EXCEPTION: Where compliance is not operationally or structurally feasible, ramps, bridge plates, or similar devices complying with the applicable requirements of 36 CFR 1192.83(c) shall...
- Wheelchair Fitness Solutionâ„¢ Complete Fitness System
-
4.1.6(3)(b)
(b) At least one accessible entrance complying with 4.14, Entrances. If additional entrances are altered then they shall comply with 4.1.6(a); and
-
§ 37.43(b)
(b) As used in this section, the phrase to the maximum extent feasible applies to the occasional case where the nature of an existing facility makes it impossible to comply fully...
-
203.1 General
EXCEPTION: In new construction, full compliance with the requirements of these standards is not required where an entity can demonstrate that it is structurally impracticable to meet the...
-
Alterations: ADA Standard Section 233.3.4
Section 233.3.4: covers scoping requirements in the current ADA Standards for alterations to residential facilities.
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
TECHNICALLY INFEASIBLE
An alteration of a building or a facility that has little likelihood of being accomplished because the existing structural conditions require the removal or alteration of a load-bearing...
-
106.5.68 Technically Infeasible
With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
4.1.6(1)(j) EXCEPTION
Means, with respect to an alteration of a building or a facility, that it has little likelihood of being accomplished because existing structural conditions would require removing or altering...
-
1.9.1.2.4
1.9.1.2.4 All existing privately funded public accommodations when alterations, structural repairs or additions are made to such public accommodations as set forth under Chapter 11B....
-
1.9.1.2.4
1.9.1.2.4 All existing privately funded public accommodations when alterations, structural repairs or additions are made to such public accommodations as set forth under Chapter 11B....
-
Accessible Routes: ADA Standard Section 1002.2
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
II-6.3100 General principles
UFAS: Application of standards is not required for alterations where "structurally impracticable," i.e., where removal of a load-bearing structural member is involved or where the result...
-
11B-1002.2 Accessible routes
Exceptions: In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 is not structurally or operationally feasible, ramp slope shall be permitted...
- Greenfields Outdoor Fitness Two-Person Accessible Vertical Press GR2005-1-47-W
- Greenfields Outdoor Fitness Two-Person Accessible Lat Pull GR2005-1-48-W
- Greenfields Outdoor Fitness Accessible Hand Cycle HP2009-7-21
- TechnoGym® - Radiant Inclusive Commercial Fitness System
- Cybex Total Access Cable Column Exercise Machine
- Greenfields Outdoor Fitness Two-Person Accessible Combo Butterfly and Reverse Fly GR2005-1-48E-W (2 Configurations)