Openings in exterior walls in adjacent stories shall be separated vertically to protect against fire spread on the exterior of the buildings where the openings are within 5 feet (1524 mm...
Search Results "Story"
Commonly Searched Documents
-
704.9 Vertical separation of openings
-
F213.1 General
Where toilet facilities and bathing facilities are provided in facilities permitted by F206.2.3 Exceptions 1 and 2 not to connect stories by an accessible route, toilet facilities and bathing...
-
Section 2. Loft
"Loft" means an intermediate level between the floor and ceiling of any story, located within a room or rooms of a dwelling....
- VisionConnect™ Mobile App
-
11B-206.6 Elevators
Elevators complying with Section 11B-408 or 11B-409 shall be permitted in multi-story residential dwelling units....
-
Jeff's Story - A Video about Living with Spina Bifida
Requires the Registered User plan or above. Login!
- Rolling On: Stories About Wheelchair Accessibility Around the World
-
International experiences
International experiences Several people relayed stories about visits to museums in other countries where all visitors could touch what is on display: ...
-
903.3.1.2 NFPA 13R sprinkler systems
Where allowed in buildings of Group R, up to and including four stories in height, automatic sprinkler systems shall be installed throughout in accordance with NFPA 13R....
-
704.7 Unexposed surface temperature
Where protected openings are not limited by Section 704.8, the limitation on the rise of temperature on the unexposed surface of exterior walls the exterior wall in any story, the total...
-
4.1.2(7)
EXCEPTION: In multiple-story buildings and facilities where at-grade egress from each floor is impossible, either of the following is permitted: the provision within each story of approved...
-
711.4.3.2 Penetrating items
Penetrating items that connect not more than two stories are permitted provided that the annular space is filled with an approved material to resist the free passage of flame and the products...
-
711.4.3.1 Noncombustible penetrating items
Noncombustible penetrating items that connect not more than three stories are permitted provided that the annular space is filled with an approved noncombustible material to resist the free...
-
206 Accessible Routes
Section 206.2 specifies where accessible routes are required within a site, including their connection to accessible buildings, stories, spaces, and elements....
-
Audio
They felt audio would be useful in relaying the story behind the map. Sound effects were also suggested to enhance the experience, especially for children....
-
Accessible Routes in Dwelling Units with Mobility Features
Section 233.3.5 of the 2010 Standards also includes an exception to the dispersion requirement that permits accessible single-story dwelling units to be constructed, where multi-story dwelling...
-
11B-206.6 Elevators
In a building or facility permitted to use the exceptions to Section 11B-206.2.3 _|Accessible Routes; Multi-Story Buildings and Facilities|_ or permitted by Section 11B-206.7 to use a platform...
-
Are freight or service elevators required to comply?
When an elevator is used to provide a required accessible route between stories, it must meet requirements for passenger elevators....
-
11B-206.6 Elevators
In a building or facility permitted to use the exceptions to Section 11B-206.2.3 _|Accessible Routes; Multi-Story Buildings and Facilities|_ or permitted by Section 11B-206.7 to use a platform...
-
1009.6.3 Size
The total number of such 30-inch by 48-inch (762 mm by 1219 mm) spaces per story shall be not less than one for every 200 persons of calculated occupant load served by the area of refuge...
-
F206.2.4 Spaces and Elements
Accessible routes shall not be required to connect mezzanines where buildings or facilities have no more than one story....
-
206.2.4 Spaces and Elements
Accessible routes shall not be required to connect mezzanines where buildings or facilities have no more than one story....
-
Elevator Exemption
Public facilities, which are defined as State and local government facilities, are permitted an exception from the requirement for access between stories (206.2.3, Exception 2)....
-
Section 2. Definitions
New terms defined in the final Guidelines include: "adaptable," "assistive device," "ground floor," "loft," "multistory dwelling unit," "single-story dwelling unit," and "story"....