(2) Within individual dwelling units, doors intended for user passage through the unit which have a clear opening of at least 32 inches nominal width when the door is open 90 degrees, measured...
Search Results "Single-Story Dwelling Unit (FHA)"
Commonly Searched Documents
-
3(2)
-
11B-208.3.3.1
Detached private garages accessory to residential dwelling units, shall be accessible as required by Section 11B-208.3....
-
Activation: ADA Standard Section 809.5.2.1
All visible alarm appliances provided within the residential dwelling unit for smoke detection notification shall be activated upon smoke detection....
-
Bathroom Design Illustrations
Comment. A number of commenters from the disability community stated that two of the six bathroom drawings in the preamble to the proposed guidelines (numbers 4 and 6 at 55 FR...
-
17.1 Q. Is it correct that only the exterior side of the main entry door of covered multifamily dwellings must meet the ANSI requirements?
The interior of the main entry door is part of the dwelling unit and only needs to meet the requirements for usable doors within the dwelling intended for user passage, i.e., at least 32...
-
Accessible Routes: ADA Standard Section 809.2
Accessible routes complying with Chapter 4 shall be provided within residential dwelling units in accordance with 809.2....
-
11B-809.2 Accessible routes
Accessible routes complying with Division 4 shall be provided within residential dwelling units in accordance with Section 11B-809.2....
-
§100.205(c)(3)
(3) All premises within covered multifamily dwelling units contain the following features of adaptable design:...
-
7(2)(b)(iv)
(iv) Toilets are located within bathrooms in a manner that permit a grab bar to be installed on one side of the fixture. In locations where toilets are adjacent to walls or bathtubs,...
-
7(2)(a)(ii)
(ii) Clear floor space is provided at fixtures as shown in Fig. 7 (a), (b), (c) and (d). Clear floor space at fixtures may overlap. Fig. 7 Clear Floor Space for...
-
Location: ADA Standard Section 809.2.1
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....
-
11B-809.2.1 Location
At least one accessible route shall connect all spaces and elements which are a part of the residential dwelling unit....
-
Additions: ADA Standard Section 233.3.3
Section 233.3.3: covers scoping requirements in the current ADA Standards for additions to residential facilities.
-
A4.34 DWELLING UNITS
[See subsections ...]
-
7(2)(a)
(a) Bathrooms that have reinforced walls for grab bars (see Requirement 6) would meet section 100.205(c)(3)(iv) if: Note: Cabinets under lavatories are acceptable provided the...
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
In elevator buildings, public housing facilities with multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential...
-
7(2)(b)(v)
(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture. The top of the fixture rim is a maximum...
-
Do stories not required to be on an accessible route have to comply with the Standards?
Yes, stories (and mezzanines) not connected by an accessible route must still meet all other applicable requirements in the Standards....
-
11B-233.3.2.1 Buyer identified residential dwelling units for sale
The requirements of Section 11B-233.3.2 also apply to housing programs that are operated by public entities where design and construction of particular residential dwelling units take place...
-
11B-203.6 Single occupant structures
Single occupant structures accessed only by passageways below grade or elevated above standard curb height, including but not limited to, toll booths that are accessed only by underground...
-
224.6.2 Facilities with Residential Units and Transient Lodging Units
224.6.2 Facilities with Residential Units and Transient Lodging Units....
-
(5) Reinforced walls for grab bars
to these guidelines has been to subject powder rooms to the reinforced wall requirement when the powder room is the only toilet facility on the accessible floor of a covered multistory dwelling...
-
F233.4.4.2 Alterations to Individual Residential Dwelling Units
residential dwelling units until the total number of residential dwelling units complies with the minimum number required by F233.4.1.1 and F233.4.1.2....
-
233.3.1.2 Residential Dwelling Units with Communication Features
233.3.1.2 Residential Dwelling Units with Communication Features....