Search Results "Single-Story Dwelling Unit (FHA)"
-
Requirement 3 -- Usable Doors
-
7.1 Q. Do the new construction requirements of the Fair Housing Act apply to continuing care facilities which incorporate housing, health care and other types of services?
The new construction requirements of the Fair Housing Act would apply to continuing care facilities if the facility includes at least one building with four or more dwelling units....
-
Identification: ADA Standard Section 809.5.5.2
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
11B-809.5.5.2 Identification
A means for visually identifying a visitor without opening the residential dwelling unit entry door shall be provided and shall allow for a minimum 180 degree range of view....
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from...
-
3. Discussion of Comments on Related Fair Housing Issues Compliance Deadline
Section 100.205 of the Fair Housing regulations incorporates the Act's design and construction requirements, including the requirement that multifamily dwellings for first occupancy after...
-
10.2 Q. Does the route leading from inside a private attached garage to the dwelling unit have to be accessible?
Under Requirement 1 of the Guidelines, there must be an accessible entrance to the dwelling unit on an accessible route....
-
11B-233.3.1.2.2 Ground floor residential dwelling units
Ground floor residential dwelling units shall be adaptable. A building may have one or more ground floors....
-
11B-233.3.1.2.2 Ground floor residential dwelling units
Ground floor residential dwelling units shall be adaptable. A building may have one or more ground floors....
-
Compliance Determinations by State and Local Jurisdictions
A few commenters questioned the role of States and units of local government in determining compliance with the Act's accessibility requirements....
-
11B-233.3.1.2.1 Elevator buildings
Residential dwelling units on floors served by an elevator shall be adaptable. Exceptions: 1....
-
11B-233.3.1.2.1 Elevator buildings
Residential dwelling units on floors served by an elevator shall be adaptable. Exceptions: 1....
-
Requirement 6. Reinforced walls for grab bars.
Section 100.205(c)(3)(iii) requires that covered multifamily dwellings with a building entrance on an accessible route shall be designed and constructed in such a manner that all premises...
-
Guidelines for Requirement 6
a powder room is subject to the requirement for reinforced walls for grab bars when the powder room is the only toilet facility located on the accessible level of a covered multistory dwelling...
-
106.5.54 Residential Dwelling Unit
A unit intended to be used as a residence that is primarily long-term in nature....
-
Additional Parking Spaces for Residents: ADA Standard Section 208.2.3.2
Section 208.2.3.2 covers scoping requirements in the current ADA Standards for additional parking spaces for residents.
-
11B-208.2.3.2 Additional parking spaces for residents
Where the total number of parking spaces provided for each residential dwelling unit exceeds one parking space per residential dwelling unit, 2 percent, but no fewer than one space, of all...
-
11B-208.2.3.2 Additional parking spaces for residents
Where the total number of parking spaces provided for each residential dwelling unit exceeds one parking space per residential dwelling unit, 2 percent, but no fewer than one space, of all...
-
Section 2. Covered multifamily dwellings
"Covered multifamily dwellings" or "covered multifamily dwellings subject to the Fair Housing Amendments" means buildings consisting of four or more dwelling units if such buildings have...
-
7(1)(a)
(a) A clear floor space at least 30 inches by 48 inches that allows a parallel approach by a person in a wheelchair is provided at the range or cooktop and sink, and either a...
-
11B-208.3.3.2
Attached private garages directly serving a single residential dwelling unit shall provide at least one of the following options: A door leading directly from the residential dwelling...
-
11B-208.3.3.2
Attached private garages directly serving a single residential dwelling unit shall provide at least one of the following options: A door leading directly from the residential dwelling...
-
Section 3. Fair Housing Act Design and Construction Requirements
This section reprints §100.205 (Design and Construction Requirements) from the Department's final rule implementing the Fair Housing Act. A reprint of §100.205 was included to...