11B-607.4 Grab bars. Grab bars for bathtubs shall comply with Section 11B-609 and shall be provided in accordance with Section 11B-607.4.1 or 11B-607.4.2....
Search Results "Shower Grab Bar"
Commonly Searched Documents
-
11B-607.4 Grab bars
-
11B-607.4 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped or U-shaped grab bar meeting the dimensional requirements of Section 11B-607.4.1 or 11B-607.4.2...
-
11B-607.4 Grab bars
Where separate grab bars are required on adjacent walls at a common mounting height, an L-shaped or U-shaped grab bar meeting the dimensional requirements of Section 11B-607.4.1 or 11B-607.4.2...
-
4.17.6 Grab Bars
Grab bars complying with the length and positioning shown in Fig. 30(a), (b), (c), and (d) shall be provided....
-
4.17.6 GRAB BARS
Grab bars complying with the length and positioning shown in Fig. 30(a), (b), (c), and (d) shall be provided....
-
6. Grab Bars
Is there a horizontal grab bar at the head of the tub that is at least 12" long for stabilization and aid in transfer from a wheelchair to the fixed tub seat - see Figure 34 on page 25?...
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar B-5837
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar B-68137
-
Shower Compartment Seats: ADA Standard Section 610.3
Section 610.3 covers the current ADA Standards for shower compartment seats.
-
11B-609.2 Cross section
Grab bars shall have a cross section complying with Section 11B-609.2.1 or 11B-609.2.2....
-
1134A.6, Item 4
Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
1134A.6, Item 4
Reinforced walls for grab bars. Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar Peened B-68137.99
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar Peened B-5837.99
-
4.20.4 Grab Bars
Grab bars complying with 4.26 shall be provided as shown in Fig. 33 and 34....
-
4.20.4 GRAB BARS
Grab bars complying with 4.26 shall be provided as shown in Fig. 33 and 34....
- Bobrick 18" Straight Grab Bar B-6806 x 18
- Bobrick 18" Straight Grab Bar B-5806 x 18
-
11B-609.8 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the grab bar, fastener, mounting device,...
- Bradley Security Grab Bars SA70 Series
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
5. Grab Bar
Is there a horizontal grab bar at the foot of the tub (by the controls) that is at least 24" long for stabilization while a person with a disability adjusts the water controls - see Figure...
- Bobrick 18" Straight Grab Bar Peened B-6806.99 x 18
- Bobrick 18" Straight Grab Bar Peened B-5806.99 x 18