Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
Search Results "Landing"
Commonly Searched Documents
-
11B-407.2.1.5 Signals
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
-
Ramp Requirements [§405]
Ramp Requirements [§405]
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
1009.10 Directional signage
At elevator landings. Within areas of refuge....
-
1007.10 Directional signage
At elevator landings. Within areas of refuge....
-
1009.10 Directional signage
At elevator landings. 3. Within areas of refuge....
-
Curb Ramp Requirements [§406]
Curb Ramp Requirements [§406]
-
5.3.6 Entrance
A 60 inch by 60 inch (1,220 millimeters by 1,220 millimeters) level landing must be provided outside the door to the toilet. Sloped entries do not require handrails....
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp. The slope of the turning space in all directions shall be...
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1. Destination-oriented elevators shall not be...
-
Common Problems with Routes to Building Entrances
Common Problems with Routes to Building Entrances Ø The route has steps but no ramp. Ø Ramps are too steep or go too long without level rest areas; handrails are not...
-
407.2.1.5 Signals
Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1. Destination-oriented elevators shall not be...
-
407.2.1.5 Signals
407.2.1.5 Signals. Call buttons shall have visible signals to indicate when each call is registered and when each call is answered. EXCEPTIONS: 1. Destination-oriented elevators...
-
11B-406.5.9 Clear space at diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1219 mm) minimum outside active traffic lanes of the roadway. Diagonal curb ramps provided at marked crossings...
-
Hall Lanterns [4.10.4]
Audible signals serve people with visual impairments by indicating which car is answering the call and its travel direction. Audible signals sound once for the up direction, twice...
-
Slope [4.7.2]
The running slope of curb ramps cannot exceed 1:12. In alterations where it is technically infeasible to meet new construction requirements, curb ramps may have a maximum slope of...
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp. The slope of the turning space in all directions shall be...
-
11B-406.5.9 Clear space at diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1219 mm) minimum outside active traffic lanes of the roadway. Diagonal curb ramps provided at marked crossings...
-
11B-406.5.9 Clear space at diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1219 mm) minimum outside active traffic lanes of the roadway. Diagonal curb ramps provided at marked crossings...
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp. The slope of the turning space in all directions shall be...
- SafePath: Overview of Ramps and Reducers for ADA Compliance by SafePath Products
-
Elevator Landing Requirements [§407.2]
Elevator Landing Requirements [§407.2]...