Ramp landing slopes specified by Section 11B-405.7.1 shall be permitted to be 1:20 maximum. 5....
Search Results "Landing"
Commonly Searched Documents
-
11B-1007.2 Accessible routes
-
B. Slopes
[ADA Stds. 4.8.2] Yes __ No __ N/A __ Comments: ___________________________________________ ...do the interior ramps have top, middle and bottom landings that are level and at least...
-
5.3.6 Entrance
A 60 inch by 60 inch (1,220 millimeters by 1,220 millimeters) level landing must be provided outside the door to the toilet. Sloped entries do not require handrails....
-
a) Curb Ramps
greater than a half-inch; 12 points for a running slope between 8.33 percent and 10 percent; 25 points for a running slope greater than 10 percent; and 13 points for lack of a level bottom landing...
-
Visible and Audible Signals: ADA Standard Section 407.2.2.1
Section 407.2.2.1 covers the current ADA Standards for elevator visible and audible signals.
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
- Filter Pave™ Porous Paving for Stormwater Management
-
4.10.4(2)
(2) Visual elements shall be at least 2‒1/2 in (64 mm) in the smallest dimension.
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
Elevator Car Requirements [§407.4.2 – §407.4.5]
407.4.2 – §407.4.5] Other requirements for elevator cars include: compliant floor surfaces a maximum 1¼” horizontal clearance between car platform sill and hoistway landing...
- Figure 406.4 Landings at the Top of Curb Ramps – Drawing from the U.S. Access Board
-
Section G: Ramps
(§405.5) G5 Does the ramp have a level landing that is at least 60" long, at the top and bottom of each ramp section?...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
1013.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
-
8 [§§ 4.3.3; 4.3.7]
8 [§§ 4.3.3; 4.3.7] Curb ramps should have at least 36 inches of clear space at the “top” of the ramp, which can be seen in the illustration to the right [below]. The 36-inch...
-
4.10.4(3)
(3) Signals shall be visible from the vicinity of the hall call button (see Fig. 20). In-car lanterns located in cars, visible from the vicinity of hall call buttons, and conforming...
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor. Such call buttons shall have visual signals to indicate when each call is registered...
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor. Such call buttons shall have visual signals to indicate when each call is registered...