(A) Are dispersed throughout the seating area;
Search Results "Horizontal Exit"
-
Sec.36.308(a)(1)(ii)(A)
-
4.3.11.1(4)
(4) A vestibule located immediately adjacent to an exit enclosure and constructed to the same fire-resistive standards as required for corridors and openings....
-
F207 Accessible Means of Egress
[See subsections ...]
-
11B-207 ACCESSIBLE MEANS OF EGRESS
[See subsections ...]
-
11B-207 Accessible means of egress.
[See subsections ...]
-
11B-207 Accessible means of egress
[See subsections ...]
-
For People with Disabilities, Which Circulation Paths Are Usable, Available, and Closest?
Exits should be marked by tactile signs that are properly located so they can be readily found by a person who is blind or has low vision from any direction of approach to the exit access...
-
4.3.11.1(5)
(5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive...
-
1009.11 Instructions
The instructions shall include all of the following: Persons able to use the exit stairway do so as soon as possible, unless they are assisting others....
-
Which Paths Are Usable Circulation Paths?
Directional sound is an audible signal that leads people to safety in a way that conventional alarms cannot, by communicating the location of exits using broadband noise....
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
1009.11 Instructions
The instructions shall include all of the following: Persons able to use the exit stairway do so as soon as possible, unless they are assisting others....
-
4.1.1(3) Areas Used Only by Employees as Work Areas
Areas that are used only as work areas shall be designed and constructed so that individuals with disabilities can approach, enter, and exit the areas....
-
4.3.11.1(6)
The area or room shall be provided with an exit directly to an exit enclosure....
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
Examples include exit-only doors with no operating hardware on the exterior side or separate enter and exit fare gates in transit stations....
-
M305.3.1.2 Diagnostic Equipment Containing a Wheelchair Space
On diagnostic equipment containing wheelchair spaces with one entry that also serves as the exit, the length of the gripping surface of horizontal standing supports shall be equal to or...
-
11B-705.1.2.2.2.2 Two entrance/exit points
Where the turning space has two entrance/exit points other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep at both entrance/ exit points, as measured...
-
§ 35.151(g)(2)
(2) Wheelchair and companion seating locations are not located on (or obstructed by) temporary platforms or other movable structures. When wheelchair seating locations are not...
-
6.9
OR b. the measurement of the vertical viewing angle (the angle between a horizontal line from the eye to the screen and a line from the eye to the top of the screen) are within the range...
-
11B-809.8.1 Door Thresholds
Primary entry doors, required exit doors, and interior doors intended for user passage shall have thresholds complying with Section 11B-404.2.5....
-
A4.3.11.3 Stairway Width
A 48 in (1220 mm) wide exit stairway is needed to allow assisted evacuation (e.g., carrying a person in a wheelchair) without encroaching on the exit path for ambulatory persons....
-
907.2.9 Group R-2
A fire alarm system shall be installed in Group R-2 occupancies where: Any dwelling unit is located three or more stories above the lowest level of exit discharge; Any...