Exceptions: Extensions shall not be required for continuous handrails at the inside turn of switchback or dogleg stairs and ramps....
Search Results "Handrail Continuity"
Commonly Searched Documents
-
11B-505.10 Handrail extensions
-
403.6 Handrails
403.6 Handrails. Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with 505. Advisory 403.6 Handrails....
-
Handrail Clearance and Cross Section [§505.5, §505.7]
Handrail Clearance and Cross Section [§505.5, §505.7] Surface requirements and clearances facilitate a power grip along the length of handrails....
-
403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with 505. Advisory 403.6 Handrails....
-
403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with 505. Advisory 403.6 Handrails....
-
Are handrails required in elevator cars?
The ADA Standards do not require handrails in elevators cars....
-
Can handrail extensions wrap or turn?
Extensions are not required for continuous handrails along switchback or dogleg ramps or at aisle ramps serving seating in assembly areas....
-
Is a center handrail required at wide stairways?
No, a center handrail at stairs is not required by the Standards. If a center handrail is provided, compliance with the handrail specifications, while advisable, is not required....
-
ADA Facilities Compliance Continuing Education Courses & Resources
ADA Facilities Compliance Continuing Education Courses & Resources by Evan Terry Associates, P.C....
-
505 Handrails
[See subsections ...]
-
505 Handrails
[See subsections ...]
-
505 Handrails
[See subsections ...]
-
4.9.4(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the bottom riser....
-
Handrail Extensions [§505.10]
Handrail Extensions [§505.10] Handrail extensions at the top and bottom must return to walls, guards, or floors and horizontal portions must comply as protruding objects....
-
Stairs
Requirement: 4.9.4(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the...
-
Handrails Along Walking Surfaces [§403.6, §505]
Handrails Along Walking Surfaces [§403.6, §505] Handrails are required at ramps with a rise greater than 6” and at stairs that are part of a means of egress, but not at other locations...
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
11B-307.2 Protrusion limits
Exception: Handrails shall be permitted to protrude 4½ inches (114 mm) maximum. Advisory 11B-307.2 Protrusion limits....
-
R409.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beyond the top and bottom of ramp runs....
-
11B-403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with Section 11B-505. [2010 ADAS] Advisory 403.6 Handrails. ...
-
11B-403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with Section 11B-505. [2010 ADAS] Advisory 403.6 Handrails....
-
11B-403.6 Handrails
Where handrails are provided along walking surfaces with running slopes not steeper than 1:20 they shall comply with Section 11B-505. Advisory 11B-403.6 Handrails....
-
R409.10.3 Bottom Extension at Stairways
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
R409.10.2 Top Extension at Stairways
At the top of a stair flight, handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beginning directly above the first riser nosing....