604.9.4 Grab Bars. Grab bars for water closets shall comply with 604.5....
Search Results "Grab Bar Height"
Commonly Searched Documents
-
604.9.4 Grab Bars
-
604.8.2.3 Grab Bars
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
604.8.2.3 Grab Bars
Grab bars shall comply with 609. A side-wall grab bar complying with 604.5.1 shall be provided on both sides of the compartment....
-
11B-609.2.2 Non-circular cross section
Grab bars with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (102 mm) minimum and 4.8 inches (122 mm)...
-
Location
We are discovering that grab bars mounted at the recommended heights and distances from the toilet, both side and rear locations , are too far away to be effective for ‘self’ assistance....
-
4.26.2* SIZE AND SPACING OF GRAB BARS AND HANDRAILS
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1-1/4 in to 1-1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
11B-609.3 Spacing
The space between the wall and the grab bar shall be 1½ inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 1½ inches (38 mm) minimum....
-
4.16.4 Grab Bars
4.16.4 Grab Bars....
- Bradley Grab Bars 1 1/2" with Concealed Mounting 812
- AJW Architectural Products UG130-A Series UG130-A12 12" Exposed Flange, 1.5" Diameter Grab Bar - Configuration A
- AJW Architectural Products UG120-A Series UG120-A12 12" Exposed Flange, 1.25" Diameter Grab Bar - Configuration A
-
4.26.2* Size and Spacing of Grab Bars and Handrails
The diameter or width of the gripping surfaces of a handrail or grab bar shall be 1‒1/4 in to 1‒1/2 in (32 mm to 38 mm), or the shape shall provide an equivalent gripping surface....
-
Clear Deck Space: ADA Standard Section 1009.4.1
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
11B-1009.4.1 Clear deck space
Where one grab bar is provided, the clear deck space shall be centered on the grab bar....
-
5.3.4 Grab Bars
Where walls or partitions are provided, grab bars complying with ABAAS section 604.5 shall be provided....
- AJW Architectural Products UG3-A Series UG3-A12 12" Concealed Snap Flange, 1.5" Diameter Grab Bar - Configuration A
- AJW Architectural Products UG2-A Series UG2-A12 12" Concealed Snap Flange, 1.25" Diameter Grab Bar - Configuration A
- AJW Architectural Products US130-A Series US130-A12 12" Exposed Flange, 1.5" Diameter Security Grab Bar - Configuration A
-
604.9.4 Grab Bars
Grab bars for water closets shall comply with 604.5....
-
604.9.4 Grab Bars
Grab bars for water closets shall comply with 604.5....
-
604.5.1 Side Wall
The side wall grab bar shall be 42 inches (1065 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1370 mm) minimum from the rear wall. ...