5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position....
Search Results "Flared Side"
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
-
Size and Clearances [4.21.2]
Size and Clearances [4.21.2] Clear floor space is specified for side transfers. Where a forward approach is provided, space at least 60 inches wide provides room for turning....
-
M19
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall?...
-
H21
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall 33 to 36...
-
Clear Floor Space [4.25.2] and Height [4.25.3]
Clear Floor Space [4.25.2] and Height [4.25.3] Clear floor space for either a forward or side approach is allowed....
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
provide options to transfer onto the short side and the long side of the surface....
-
404.2.4.3 Recessed Doors and Gates
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the...
- 609.4 Side Wall Grab Bar Height
-
404.2.4.3 Recessed Doors and Gates
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the...
-
404.2.4.3 Recessed Doors and Gates
Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches (455 mm) of the latch side of a doorway projects more than 8 inches (205 mm) beyond the...
-
Medical Diagnostic Equipment Accessibility Standards Sub Committee Recommendations Stretcher Final Report
Specifically, Section M301, Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position....
-
5.6.1 Stirrups for Equipment Used by Patient in Supine, Prone, or Side-Lying Position
5.6.1 Stirrups for Equipment Used by Patient in Supine, Prone, or Side-Lying Position....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side....
-
6.3(1)
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement in 4.13.6 for maneuvering space at the latch side of the door if the door is...
-
11B-604.5 Grab bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
11B-604.5 Grab bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall....
-
M301 Diagnostic Equipment used by Patients in a Supine, Prone, or Side-lying Position (Section-by-Section Analysis)
M301 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a supine, prone, or side-lying position such as, examination tables, imaging tables...
-
Grab Bars: ADA Standard Section 604.5
Section 604.5 covers the current ADA Standards for grab bars that are used for water closets.
-
A4.16.4 Grab Bars
A6(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
-
A4.16.4 GRAB BARS
A5(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
-
Grab Bars [4.16.4]
Grab Bars [4.16.4] The back grab bar is most usable from the open side. It must be 36 inches long minimum, installed with one end space a maximum of 6 inches from the side wall....