- Figure 404.2.4.1(b) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side – Drawing from the U.S. Access Board
- Figure 404.2.4.1(c) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Push Side with Closer and Latch – Drawing from the U.S. Access Board
-
4.16.4* Grab Bars
Grab bars for water closets not located in stalls shall comply with 4.26 and Fig. 29. The grab bar behind the water closet shall be 36 in (915 mm) minimum.
-
4.16.4* GRAB BARS
Grab bars for water closets not located in stalls shall comply with Fig. 29 and 4.26.
-
Wheelchair Transfer
ADAAG specifications are based on three types of transfer: diagonal, perpendicular, and side, some of which are illustrated in ADAAG Appendix Figure A6....
-
M301 Diagnostic Equipment Used by Patients in Supine, Prone, or Side-Lying Position; M302 Diagnostic Equipment Used by Patients in Seated Position
M301 provides technical criteria for diagnostic equipment used by patients in a supine, prone, or sidelying position, and M302 provides technical criteria for diagnostic equipment used by...
-
M302.2.5 Unobstructed Transfer (Section-by-Section Analysis)
In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as they...
-
M302.2.5 Unobstructed Transfer
Each transfer side complying with M302.2.4 shall provide unobstructed access to transfer surfaces. EXCEPTIONS: 1....
-
Re: DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
This drawing should show that the gutter is not included in the required min 18’ depth. The dashed lines don’t spell it out clearly enough to me.
-
Re: DSA Drawing 11B-406-1C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Interesting issue/drawing. If the slope of the gutter is greater than 1:48, can they merely show it outside of the required 18' deep accessible parking space and access aisle? If...
-
5.4.1.1 Transfer Support Location Recommendation for Stretchers
Rationale for the recommendation Patients access stretchers on either of the long sides rather than on its end (short side)....
-
Water Closet Clearance
The 1991 Standards allow the nearest side of a lavatory to be placed 18 inches minimum from the water closet centerline and 36 inches minimum from the side wall adjacent to the water closet...
-
Location and Size
The side rails are similar in shape to grab bars and are located on each of the long sides of the table....
-
308.3.2 Obstructed High Reach
The high side reach shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (255 mm) maximum....
-
308.3.2 Obstructed High Reach
The high side reach shall be 48 inches (1220 mm) maximum for a reach depth of 10 inches (255 mm) maximum....
-
DSA Drawing 11B-406-12 Diagonal Curb Ramp with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-308.3.2 Obstructed high reach
The high side reach shall be 48 inches (1219 mm) maximum for a reach depth of 10 inches (254 mm) maximum....
-
Clear Floor Space [§309.2]
Clear Floor Space [§309.2] Clear floor space can be oriented for a side approach instead of a forward approach at most operable parts....
-
d. Unobstructed Transfer
and the outer edge of the equipment on the side used for transfer,” that applies to both the long length (width) and short length (depth) transfer sides....
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
308.3.2 Obstructed High Reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (865 mm) maximum...
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
5.4.1.1 Transfer Support Location for Stretchers
The transfer surface for stretchers should be oriented along the long side of the surface....